{"product_id":"gsm-lte-modulis-elmes-gsm2000lte-2g-4g-sms-clip-10-30-v-dc-12-25-v-ac","title":"GSM\/LTE modulis ELMES GSM2000LTE, 2G\/4G, SMS\/CLIP, 10-30 V DC, 12-25 V AC","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: GSM\/LTE modulis ELMES GSM2000LTE, 2G\/4G, SMS\/CLIP, 10-30 V DC, 12-25 V AC. Kategorija: Išoriniai moduliai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Elmes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e GSM2000LTE\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eGSM2000LTE - GSM 2G \/ 4G LTE module - ELMES .\u003c\/h2\u003e\u003cp\u003eThe device is designed to notify about events in alarm systems and control systems using SMS and CLIP messages, in the 2G and 4G LTE mobile network. The module also allows you to remotely control devices connected to its outputs using SMS and CLIP.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003emodule power supply: 10-30 VDC or 12. .25VAC with a current capacity of at least 1A, resting current of 3 mA;\u003c\/li\u003e\n\u003cli\u003eexternal dimensions: (L\/W\/D) 96\/63\/28mm without antenna;\u003c\/li\u003e\n\u003cli\u003e4 inputs with voltage level 0. .24V (relative to mass i.e. “-” power supply terminal),\u003c\/li\u003e\n\u003cli\u003enotification of up to 6 telephones;\u003c\/li\u003e\n\u003cli\u003e4 relay outputs type NO\/NC, with a load capacity of 0,5A\/130VAC, 1A\/30VDC;\u003c\/li\u003e\n\u003cli\u003econtrol of outputs from up to 2048 phones;\u003c\/li\u003e\n\u003cli\u003eoperating temperature range: -20 to +70ºC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe following are the most important features of the module:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4 inputs, each with programmable switching voltage level in the range of 0,2 - 14,5V and programmable hysteresis in the range of 0,1 - 5V,\u003c\/li\u003e\n\u003cli\u003e4 relay outputs, galvanically separated, NO (normally open) or NC (normally compact) type\u003c\/li\u003e\n\u003cli\u003emode of switching on outputs: monostable (time switching) or bistable (on\/off),\u003c\/li\u003e\n\u003cli\u003eswitching on outputs via SMS or CLIP from up to 2048 phones,\u003c\/li\u003e\n\u003cli\u003eswitching on outputs by violating the module input,\u003c\/li\u003e\n\u003cli\u003ememory of 1790 CLIP and SMS events;\u003c\/li\u003e\n\u003cli\u003eSMS and CLIP notification sent to up to 6 phone numbers,\u003c\/li\u003e\n\u003cli\u003ethe ability to remotely add and remove phones supported by the module;\u003c\/li\u003e\n\u003cli\u003eseparate memory of administrators and ordinary users;\u003c\/li\u003e\n\u003cli\u003eperiodic test of the module in the form of SMS or CLIP to one or two numbers\u003c\/li\u003e\n\u003cli\u003etelephones, sent at a specific time of day or every specified time;\u003c\/li\u003e\n\u003cli\u003eStatus SMS about the status of all module inputs and outputs;\u003c\/li\u003e\n\u003cli\u003eTAMPER switch for opening the module housing,\u003c\/li\u003e\n\u003cli\u003elimiting the number of SMS messages sent during the day, with the possibility of disabling it;\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eProgramming of settings and updating of the system software (firmware) of the module is performed from the level of a personal computer (PC) with Windows®, using the configuration program \"GSM2 Configurator\", which is available for download from the manufacturer's website ELMES ELEKTROIK.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eModule INPUTS\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe module has \u003cb\u003e4 inputs\u003c\/b\u003e control with a maximum, permissible level of input voltage\u003c\/p\u003e\u003cp\u003erelative to the weight of the module (minus the supply voltage) 24VDC\u003c\/p\u003e\u003cp\u003eUsing the \"GSM2 Configurator\" program, the following parameters are determined for each input separately:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eswitching voltage level in the range of 0,2 – 14,5V, and hysteresis from 0,1 to 5V for each input,\u003c\/li\u003e\n\u003cli\u003ewhether the active (switching) level of the input is high (H) or low (L) voltage,\u003c\/li\u003e\n\u003cli\u003eInput sensitivity, i.e. the minimum duration of the entry breach after which it will be considered valid.\u003c\/li\u003e\n\u003cli\u003eadjustment range: 0,2s.. .65536s with an accuracy of 0,1s.\u003c\/li\u003e\n\u003cli\u003etime of freezing the entrance after its violation in the range from 0 to 255 s with a step every 1 s.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAfter violating the input and notifying CLIP or SMS, the countdown takes place,\u003c\/p\u003e\u003cp\u003ewhen subsequent entry violations will not trigger CLIP or SMS notifications.\u003c\/p\u003e\u003cp\u003eThis avoids the situation when the module sends a series of CLIP or SMS, if its input is stimulated by a series of short pulses, e.g. from the motion detector.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003etelephones to which you should send SMS when switching on the input (change of state from inactive to active),\u003c\/li\u003e\n\u003cli\u003etelephones to which SMS should be sent when turning off the input (change of state from active to inactive),\u003c\/li\u003e\n\u003cli\u003econtent of SMS messages sent when the input is switched on and off (maximum 63 characters),\u003c\/li\u003e\n\u003cli\u003ephones to which you need to make a CLIP notification (ringing) when the input is switched on.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhen notifying CLIP, when the number is busy or unavailable, the module repeats 2 more times the attempt to connect to this number,\u003c\/p\u003e\u003cp\u003eHowever, it previously links to other numbers on the list. After making these calls, it returns to unrealized connections.\u003c\/p\u003e\u003cp\u003eIt considers a connection that:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ewas rejected;\u003c\/li\u003e\n\u003cli\u003ehas been received and subsequently terminated by the recipient;\u003c\/li\u003e\n\u003cli\u003ewas received by the recipient, but completed by the module, because the set notification time (up to 99s) expired;\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIf the call has neither been rejected nor received, but the set notification time (up to 99s) has expired, the module will accept,\u003c\/p\u003e\u003cp\u003ethat the connection has not been completed and will try to repeat it 2 times. This function can be disabled – then the module rings only once.\u003c\/p\u003e\u003cp\u003eIt is possible to interrupt the CLIP notification queue after the first successful notification (if any recipient has rejected the call, the module will not notify the remaining numbers).\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOUTPUTS OF THE Module\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe module has 4 relay outputs.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eTwo contacts of each relay are output to the installation terminals, and the jumpers set the NO or NC type of operation.\u003c\/p\u003e\u003cp\u003eFor each output, the following parameters are specified in the \"GSM2 Configurator\" program:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eoutput name (up to 16 characters maximum),\u003c\/li\u003e\n\u003cli\u003eone of the four operating modes,\u003c\/li\u003e\n\u003cli\u003ewhether the relay is to be switched on or off when the output is activated,\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOutput control can be done by sending an SMS message to the module.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe user specifies:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ewhether the SMS message must start with a password,\u003c\/li\u003e\n\u003cli\u003ewhether the SMS message can be sent from any number or only from selected numbers from the list,\u003c\/li\u003e\n\u003cli\u003ewhether the letter size of the message is relevant,\u003c\/li\u003e\n\u003cli\u003ewhether the module is to send an SMS back with confirmation of execution, or – in case of an error – rejection of SMS.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOutput control can also be done by calling the phone number of the module from one of the 2048 numbers in the list.\u003c\/p\u003e\u003cp\u003eFor each of these phones, it is determined which output it will control (you can control several outputs at the same time).\u003c\/p\u003e\u003cp\u003eThis method allows you to switch on outputs only for pre-programmed time (monostable mode),\u003c\/p\u003e\u003cp\u003ebut not permanently (bistable mode is not available).\u003c\/p\u003e\u003cp\u003eThe last, third way to control outputs – by violating the input – allows you to turn on\u003c\/p\u003e\u003cp\u003eany exit or multiple exits at once by violating a specific input.\u003c\/p\u003e\u003cp\u003eThe output can be switched on as monostable (for modes 1 and 2) or bistable (for modes 3 and 4)\u003c\/p\u003e\u003cp\u003e\u003cb\u003eNote!!!\u003c\/b\u003e – FULL technical description, i.a. Module connectivity test ; Module status ; REMOTE addition and removal of phones ; Event memory ; AT commands (for advanced operation) ; Module programming and its installation, can be found in the manual from GSM2000LTE (J. Polish) and on the Manufacturer's website ELMES ELEKTRONIK.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe GSM2000LTE module can also be controlled using the Elmes Elektronik application (see additional downloads), or universal downloads on the App Store and Google Play.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe module requires configuration in the \"GSM Configurator\" program. Before starting this process, we recommend that you update your firmware to the latest version. All downloads in the links at the top of the page. For proper operation with your computer, download and install the kabal miniUSB, and GSM2\/GSM2000 configurator drivers. D\u003c\/p\u003e\u003cp\u003eIf we have a list of phones in the form of a text file and we would like to upload it to the module, you can use a text editor that allows you to copy and paste a column of text, e.g. notepad++. To do this, paste the list of phones into the settings file, previously read from the module and saved to disk.\u003c\/p\u003e\u003cp\u003eThe firmware update of the module is done in GSM2 Configurator in Menu -\u0026gt; Tools -\u0026gt; Firmware Update.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGSM2000LTE\u003c\/b\u003eand older GSM2 and GSM2000\u003cb\u003e consist of GSM module, GSM antenna and housing.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe module programming cable is an additional component and is not included.\u003c\/p\u003e\u003cp\u003eGSM modules offered since December 2010 are equipped with a mini USB port - type B and require a popular mini-USB cable to connect to a PC.\u003c\/p\u003e\u003cp\u003eThe program \"GSM Configurator\" uses the library: \"Microsoft . NET Framework 2.0\". It is recommended to install its latest version from \"Service Pack 2\".\u003c\/p\u003e\u003cp\u003eYou can also install: \"Microsoft Framework 3.5 Service Pack 1\", which includes i.a. \"Microsoft. NET Framework 2.0 SP2\".\u003c\/p\u003e\u003cp\u003e\u003cb\u003eALL ELMES products are in adjacent auctions.\u003c\/b\u003e\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eother\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModuł GSM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eElmes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eGSM2000LTE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5906692702060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCertificates of conformity\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ALERTUS","offers":[{"title":"Default Title","offer_id":54077421158747,"sku":"17140720249","price":103.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/GSM2000LTE-GSM-2G-4G-LTE-module-SMS-CLIP-10-30-VDC-or-12-25-VAC-ELMES.jpg?v=1789558838","url":"https:\/\/homy.lt\/lv\/products\/gsm-lte-modulis-elmes-gsm2000lte-2g-4g-sms-clip-10-30-v-dc-12-25-v-ac","provider":"homy.lt","version":"1.0","type":"link"}