{"product_id":"sieninis-rekuperatorius-warmtec-rw470-160-mm-60-m-val-wifi-nuotolinis-valdymas","title":"Sieninis rekuperatorius Warmtec RW470, 160 mm, 60 m³\/val., WiFi, nuotolinis valdymas","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Sieninis rekuperatorius Warmtec RW470, 160 mm, 60 m³\/val., WiFi, nuotolinis valdymas. Kategorija: Rekuperacinės vėdinimo sistemos.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Warmtec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e RW470\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDecentralized wall recuperator 160 mm Wi-Fi 60 m³\/h + remote control Warmtec RW470\u003c\/h2\u003e\u003ch2\u003e⚡ How does an air recuperator work?\u003c\/h2\u003e\u003cp\u003eThe air recuperator is responsible for the exchange of air in the room. It removes used, moist and polluted air, and in its place blows fresh air from the outside.\u003c\/p\u003e\u003cp\u003eThe biggest advantage of the recuperator is \u003cb\u003eheat recovery\u003c\/b\u003e. This means that the device uses heat from the air removed from the room to pre-heat the fresh air supplied from the outside.\u003c\/p\u003e\u003cp\u003eThanks to this, you can regularly ventilate the room without such large heat losses as with traditional window ventilation. This is especially useful in autumn and winter, when you care about the fresh air, but do not want to cool the interior.\u003c\/p\u003e\u003ch2\u003e💡 What distinguishes the Warmtec RW470 recuperator?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Heat recovery up to 97%\u003c\/b\u003e — the device helps to exchange air without large energy losses, so that the \u003cb\u003eroom is ventilated\u003c\/b\u003e, and the \u003cb\u003eheat \u003c\/b\u003e\u003cb\u003edoes not escape so quickly\u003c\/b\u003e outside.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Wi-Fi control via Tuya Smart\u003c\/b\u003e app — allows you to \u003cb\u003econtrol \u003c\/b\u003e\u003cb\u003ework \u003c\/b\u003e\u003cb\u003edevices \u003c\/b\u003efrom your smartphone, set modes, fan speed and work schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Three fan speeds — \u003c\/b\u003e allow you to adjust the intensity of the device to your current needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ \u003c\/b\u003e\u003cb\u003eTurbo\u003c\/b\u003e mode — allows you to start the fan with \u003cb\u003emaximum power\u003c\/b\u003e for a specified period of time when more intensive air exchange is needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Ionization capability\u003c\/b\u003e – the recuperator has the function of turning on the negative ion generator power supply, which can support the improvement of the quality of the supplied air; the \u003cb\u003eion generator is an optional element and must be purchased separately\u003c\/b\u003e. ⚠\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e🌬 Three modes of recuperator operation\u003c\/h2\u003e\u003cp\u003eThe Warmtec RW470 recuperator can operate in three modes: \u003cb\u003eair supply, exhaust and recuperation\u003c\/b\u003e. Thanks to this, the user can adjust the operation of the device to the current need – bring fresh air, remove used air or use air exchange with heat recovery.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e✅ \u003cb\u003eAir supply mode — \u003c\/b\u003ein this mode, the recuperator draws air from the outside and introduces it into the room. This is a good solution when you want to quickly improve the freshness of the air inside.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eExhaust mode — \u003c\/b\u003eIn this mode, the device draws air out of the room and removes it outside. It works well when you want to get rid of puffiness, moisture or unpleasant odors.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eRecuperation mode — \u003c\/b\u003ein this mode, the recuperator works alternately: once it removes air from the room, and once it blows fresh from the outside. Thanks to the ceramic exchanger, the device recovers some of the heat from the exhaust air, so the room is ventilated without so much cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e📊 Technology and parameters in practice\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Recuperation mode with cycles every 75 seconds \u003c\/b\u003e — the device alternately blows and exhausts air to recover heat and moisture from the air removed from the room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅\u003c\/b\u003e\u003cb\u003e Maximum airflow of 60 m³\/h —\u003c\/b\u003e the device ensures effective air exchange in a single room.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅\u003c\/b\u003e\u003cb\u003e Low power consumption of 7,8 W\u003c\/b\u003e — the recuperator can work regularly, consuming a small amount of energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Noise level 32,7 dB(A)\u003c\/b\u003e — the device operates relatively quietly, so it can be used in everyday spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ 12-hour timer\u003c\/b\u003e – allows you to schedule the operating time of the device, so that the recuperator can automatically operate for a specified period of time without having to manually turn off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Wall mounting 280 – 470 mm\u003c\/b\u003e – telescopic design allows you to adjust the device to different wall thicknesses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ IPX4\u003c\/b\u003e rating – The housing provides increased splash protection, as intended and in accordance with installation recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✅ Energy efficiency class A\u003c\/b\u003e – the device combines effective ventilation with energy-efficient operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e🌬 CO₂ control — fresh air when needed\u003c\/h2\u003e\u003cp\u003eThe Warmtec RW470 recuperator can work with a CO₂ sensor that monitors indoor air quality. If the carbon dioxide concentration exceeds the set value, the device will automatically change the way it works to provide more fresh air from the outside.\u003c\/p\u003e\u003cp\u003eWhen the recuperator is in regeneration mode and the sensor detects too high a concentration of CO₂, the device will switch to \u003cb\u003eair mode\u003c\/b\u003e. Thanks to this, fresh air will enter the room, which will help reduce CO₂ levels.\u003c\/p\u003e\u003cp\u003eAfter the CO₂ concentration drops below the set value, the recuperator will return to its previous operating mode.\u003c\/p\u003e\u003ch2\u003e🌿 Free cooling – fresh air without heat recovery\u003c\/h2\u003e\u003cp\u003eThe Warmtec RW470 recuperator has a \u003cb\u003efree cooling\u003c\/b\u003e function, which allows you to use the comfortable outdoor air temperature to ventilate the room.\u003c\/p\u003e\u003cp\u003eWhen the outside temperature is within the set range, the device can operate in \u003cb\u003eair supply mode\u003c\/b\u003e, delivering fresh air from the outside without heat recovery.\u003c\/p\u003e\u003cp\u003eThis is a practical solution especially when it is pleasantly cool outside, and the room has become too warm or stuffy.\u003c\/p\u003e\u003ch2\u003e📱 Convenient control of recuperator from the application\u003c\/h2\u003e\u003cp\u003eWhen you connect the Warmtec RW470 recuperator to the \u003cb\u003eTuya Smart\u003c\/b\u003e app, you can conveniently control the most important functions of your device from your phone.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Turning the device on and off\u003c\/b\u003e — fast operation without approaching the recuperator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Selection of operating mode\u003c\/b\u003e — switching between air supply, exhaust and recuperation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Fan speed control\u003c\/b\u003e – adjust the air exchange intensity to your current needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Work schedule setting\u003c\/b\u003e — scheduling when the recuperator is to work automatically.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Preview of operating mode thanks to LED\u003c\/b\u003e – the color of the diode informs in which mode the device is currently operating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Clear signaling on the device\u003c\/b\u003e — green LED means airflow, red exhaust, and blue recuperation mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e✔ Device status preview\u003c\/b\u003e – quickly check the current settings and operating mode in the application\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e🔄 Leader-observer system – better air exchange\u003c\/h2\u003e\u003cp\u003eThe Warmtec RW470 recuperator can work with a second device in the \u003cb\u003eleader-observer\u003c\/b\u003e system. This means that the two recuperators can be combined to work together and complement their work.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e👉 Leader\u003c\/b\u003e is the main device – responsible for controlling the operation of the second recuperator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e👉 Observer\u003c\/b\u003e is a subordinate device — it operates according to the mode set by the leader.\u003c\/li\u003e\n\u003cli\u003e👉 \u003cb\u003eThe pilot controls the leader\u003c\/b\u003e device – after setting the leader-observer system, the pilot supports only the recuperator set as the leader, and the observer works according to its settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e👉 Alternating operation\u003c\/b\u003e allows for more balanced ventilation – when one device supplies fresh air, the other removes used air at that time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e👉 Better air circulation\u003c\/b\u003e works especially well in larger rooms or when you want to exchange air more effectively.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e🛠 Installation of a recuperator – what is worth knowing?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e✅ \u003cb\u003eWall mount \u003c\/b\u003e- the device is mounted directly in the external wall so that it can exchange air between the room and the environment.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eMounting hole approx.\u003c\/b\u003e \u003cb\u003e17 cm \u003c\/b\u003e- for installation, prepare a round hole in the wall with a diameter of about \u003cb\u003e17 cm\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eFor walls with a thickness of 280 – 470 mm\u003c\/b\u003e - telescopic channel design allows you to adjust the device to different wall thicknesses.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eRecommended installation height: minimum 2,1 m \u003c\/b\u003e- installation at the appropriate height supports proper air circulation in the room.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eSealing with PU\u003c\/b\u003e foam - the gap between the channel and the wall should be filled with PU foam to stably embed the channel and reduce leaks.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eWater protection from the inside\u003c\/b\u003e - an appropriate seal should be applied from the side of the room to reduce the risk of moisture entering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e🧼 Recuperator Maintenance – Simple Care for Efficient Operation\u003c\/h2\u003e\u003cp\u003eIn order for the Warmtec RW470 recuperator to work efficiently and quietly, it is worth regularly checking its filter elements and keeping the device clean.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e✅ \u003cb\u003eFilter F7 - \u003c\/b\u003eFilter F7 should be checked, vacuumed or replaced regularly - it should not be washed with water.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eFilter cleaning alarm - \u003c\/b\u003eThe device can remind you to clean or replace the filter, which makes it easier to maintain proper operation.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eCeramic heat exchanger - \u003c\/b\u003ethe heat exchanger should be cleaned at least 4 times a year and left to dry completely after washing.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eFan cleaning - \u003c\/b\u003erotor blades should be cleaned at least once a year using a soft brush, cloth or vacuum cleaner.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cb\u003eSafe maintenance - \u003c\/b\u003ebefore cleaning or replacing components, the device must be disconnected from the power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e📦 Composition of the set:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDecentral recuperator\u003c\/b\u003e \u003cb\u003eWarmtec RW470\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting accessories\u003c\/b\u003e (included: 4 pegs and screws for rain cover, handle, nut, 1 pin and screw for main recuperator device)\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eRemote control\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating instructions\u003c\/b\u003e\u003cb\u003eand in Polish\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e⚙ Technical specification:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e Warmtec RW470\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDevice type:\u003c\/b\u003e decentralized recuperator\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower supply voltage:\u003c\/b\u003e 230 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency:\u003c\/b\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower consumption:\u003c\/b\u003e 7,8 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectricity:\u003c\/b\u003e 0,06 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRotations:\u003c\/b\u003e 1000 \/ 1500 \/ 1800 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum turnover:\u003c\/b\u003e 2200 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum airflow:\u003c\/b\u003e 60 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAir flow in recuperation mode with filter F7:\u003c\/b\u003e 20 \/ 40 \/ 50 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNoise level:\u003c\/b\u003e 32,7 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHeat recovery efficiency:\u003c\/b\u003e up to 97%\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProtection rating:\u003c\/b\u003e IPX4\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAir channel diameter:\u003c\/b\u003e 158 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSeasonal energy efficiency index:\u003c\/b\u003e class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAssembly type:\u003c\/b\u003e wall mounted \/ through wall\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWall thickness:\u003c\/b\u003e 280 – 470 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWorking temperature range:\u003c\/b\u003e from -20°C to +50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRelative operating humidity:\u003c\/b\u003e less than 80%\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProtection class:\u003c\/b\u003e II\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003e⚡ How does a recuperator work?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe device alternately blows and blows air, and the ceramic exchanger helps to recover some of the heat from the air removed from the room.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ How is a recuperator different from a regular fan?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eAn ordinary fan only moves or removes air, and the recuperator additionally recovers heat and helps to reduce cooling of the room.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Does the recuperator heat the room?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIt is not a heating device, but it recovers some of the heat from the exhaust air and transfers it to fresh supply air.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Can a recuperator replace window ventilation?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe recuperator helps to change air regularly without opening windows frequently, but it does not always completely replace the classic airing in every situation.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Can a recuperator help with steaming windows?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eYes, improving ventilation and removing moist air can reduce the evaporation of windows.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Does the recuperator work with 5 GHz Wi-Fi?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eNo, a router operating in the 2,4 GHz band is required to configure a Wi-Fi connection.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Does the recuperator require a duct installation?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eNo, the RW470 is a wall-mounted decentral recuperator, so it does not require extensive duct installation throughout the building.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ What hole do I need to make for the installation of the recuperator?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eFor installation, prepare a round hole in the wall with a diameter of about 17 cm.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ To what wall thickness does the device fit?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe telescopic design allows the recuperator to be mounted in walls with a thickness of 280 to 470 mm.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Do filters need to be replaced?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eFilters should be cleaned or replaced depending on the degree of dirt and operating conditions of the device.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Can the device be cleaned with water?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eNo, water, solvents, abrasives or sharp objects should not be used for cleaning.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e⚡ Do I need to disconnect the device from electricity before maintenance?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eYes, before cleaning or maintenance, the recuperator must be disconnected from the power supply.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWarmtec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eheat recovery ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eRW470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eRange of energy efficiency classes\u003c\/td\u003e\n\u003ctd\u003eA+ - G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Warmtec","offers":[{"title":"Default Title","offer_id":53908939931995,"sku":"18682112266","price":367.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/Decentralized-wall-recuperator-160-mm-WiFi-60-m3-h-remote-control-Warmtec-RW470.jpg?v=1787924790","url":"https:\/\/homy.lt\/lv\/products\/sieninis-rekuperatorius-warmtec-rw470-160-mm-60-m-val-wifi-nuotolinis-valdymas","provider":"homy.lt","version":"1.0","type":"link"}