{"product_id":"slegio-jungiklis-hidroforui-sk-6a-1-4-isorinis-sriegis","title":"Slėgio jungiklis hidroforui SK-6A, 1\/4\" išorinis sriegis","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Slėgio jungiklis hidroforui SK-6A, 1\/4\" išorinis sriegis. Kategorija: Siurbliai ir hidroforai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e BG-INVEST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e BG-00021\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003e✅PRESSURE SWITCH FOR SK-6A MALE PUMP\u003c\/h2\u003e\u003cp\u003e\u003cb\u003e➡ \u003c\/b\u003eThe SK-6A male \u003cb\u003epressure switch acts as a control for the operation of a hydrophore or submersible pump\u003c\/b\u003e, especially in combination with a tank.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e➡ \u003c\/b\u003eAfter installation and tuning, the \u003cb\u003eswitch starts or turns off\u003c\/b\u003e the pump motor depending on the current pressure in the system. Thanks to this solution, the pump motor does not work non-stop, which ensures \u003cb\u003eoptimal functioning of the hydrophore set\u003c\/b\u003e.\u003c\/p\u003e\u003cp\u003e➡ Installation of the pressure switch is \u003cb\u003eextremely easy\u003c\/b\u003e. It is enough to fix it in a designated place, for example, at the discharge output of a five-way output.\u003c\/p\u003e\u003cp\u003e➡ To connect the wires, remove the gray plastic housing (this solution is hooked by unscrewing the screw). The diameter of the connection stub is \u003cb\u003e1\/4 inch\u003c\/b\u003e, and the tip is \u003cb\u003emale thread \u003c\/b\u003e (marked as GZ).\u003c\/p\u003e\u003cp\u003e➡ Thanks to \u003cb\u003esimple installation \u003c\/b\u003ethe use of a pressure switch becomes convenient and pleasant. The switch has knobs for \u003cb\u003e manual adjustment\u003c\/b\u003e of pressure settings. These regulatory elements are placed under the gray housing.\u003c\/p\u003e\u003cp\u003e➡ The switch allows \u003cb\u003eadjustment of the pressure\u003c\/b\u003e at which the switching takes place, in the range from 1,2 to 2,6 Bar, while for switching off the pressure, this range is from 2,1 to 5 Bar. Thanks to this, the user has \u003cb\u003efull control over the operating parameters\u003c\/b\u003e of the pressure switch.\u003c\/p\u003e\n\u003cp\u003e➡ Model: \u003cb\u003eSK-male\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Size of the slit: \u003cb\u003e1\/4\"\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Thread: \u003cb\u003eGZ\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Power supply: \u003cb\u003e230V\/50Hz\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Max. Current: \u003cb\u003e12 A\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Switching pressure adjustment range: \u003cb\u003e1,2 - 2,6 Bar\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e➡ Shut-off pressure adjustment range: \u003cb\u003e2,1 - 5 Bar\u003c\/b\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eSet the set\u003c\/b\u003e on a stable substrate, in a dry place protected against frost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnect the suction hose\u003c\/b\u003e, terminated with a suction basket with a check valve. Take care of the tightness of all connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInstall pressure gauge and pressure switch\u003c\/b\u003e — on a five-way connector or directly in the pump body, depending on the model. Seal the threads with Teflon tape or tows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnect the pump to the tank\u003c\/b\u003e with the appropriate hose, and connect the discharge output to the receiving system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnect the pump to the pressure switch.\u003c\/b\u003e The pump cable is cut into two sections: one comes out of the engine and the other is terminated with a plug. Enter both sections through the switch culverts. Connect L and N conductors from the motor to the pump terminals, and L and N conductors from the plug to the power terminals. Connect the yellow-green PE conductors of both sections to the protective clamps. Follow the scheme of the switch. Tighten clamps and culverts and close the housing. Do all the steps with the plug removed from the outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePour and vent the pump and suction hose\u003c\/b\u003e, then start the kit and check the tightness and operation of the switch.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003col\u003e\n\u003cli\u003eTurn off the pump and disconnect the power. Open the flood hole or connection shown in the illustration.\u003c\/li\u003e\n\u003cli\u003eFill the pump and suction line with clean water. Add slowly until the system is full and the water level stops dropping.\u003c\/li\u003e\n\u003cli\u003eClose the flood hole tightly or restore the discharge connection if the flooding was carried out through a connector or a five-way connector.\u003c\/li\u003e\n\u003cli\u003eOpen the tap on the discharge side and start the pump. Observe the water flow and pressure gauge.\u003c\/li\u003e\n\u003cli\u003eIf the pump does not draw water, turn it off and flood the system again. Repeat the action if necessary. If the problem persists, check the tightness of the suction line and check valve.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIMPORTANT! Do not allow the pump to run dry. Pour and vent before the first start and after each longer break in use.\u003c\/p\u003e\n\u003ch2\u003e✅ SK-6A male pressure switch\u003c\/h2\u003e\n\u003ch2\u003e✅ User manual in Polish\u003c\/h2\u003e\n\u003ch2\u003e✅ Original packaging\u003c\/h2\u003e\u003ch2\u003eExample of a hydrophore kit connection scheme\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003eHydrophore pump\u003c\/li\u003e\n\u003cli\u003eDiaphragm tank\u003c\/li\u003e\n\u003cli\u003ePump accessories with pressure switch\u003c\/li\u003e\n\u003cli\u003eSuction tube\u003c\/li\u003e\n\u003cli\u003eAnti-sand filter\u003c\/li\u003e\n\u003cli\u003eAnti-sand filter valve\u003c\/li\u003e\n\u003cli\u003eCheck valve\u003c\/li\u003e\n\u003cli\u003eButterfly Nipple Ball Valve\u003c\/li\u003e\n\u003cli\u003eNipple ball valve with handle\u003c\/li\u003e\n\u003cli\u003eProtection against dry running\u003c\/li\u003e\n\u003cli\u003eFlood tee\u003c\/li\u003e\n\u003cli\u003eFlow water filter\u003c\/li\u003e\n\u003cli\u003ePressure regulator with pressure gauge\u003c\/li\u003e\n\u003cli\u003ePE coupling\u003c\/li\u003e\n\u003cli\u003ePE pipe\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith a VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBG-INVEST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003esurface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEngine power\u003c\/td\u003e\n\u003ctd\u003e0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eBG-00021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5905771561451\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMaximum pump output\u003c\/td\u003e\n\u003ctd\u003e0 l\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HYDROMARIO_PL","offers":[{"title":"Default Title","offer_id":54641183981915,"sku":"17047583762","price":25.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/PRESSURE-SWITCH-FOR-HYDROPHORE-PUMP-SK-6A-MALE-GZ-1-4.jpg?v=1793859923","url":"https:\/\/homy.lt\/lv\/products\/slegio-jungiklis-hidroforui-sk-6a-1-4-isorinis-sriegis","provider":"homy.lt","version":"1.0","type":"link"}