{"product_id":"elektroninis-ph-matuoklis-su-automatinio-kalibravimo-funkcija","title":"Elektroninis pH matuoklis su automatinio kalibravimo funkcija","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Elektroninis pH matuoklis su automatinio kalibravimo funkcija. Kategorija: Filtruojantys ąsočiai ir buteliai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Tessa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e other (PH-03)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedžiaga:\u003c\/strong\u003e synthetic material\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eWaterproof housing\u003c\/li\u003e\n\u003cli\u003eInterchangeable measuring electrodes\u003c\/li\u003e\n\u003cli\u003eSimultaneous measurement of pH and temperature\u003c\/li\u003e\n\u003cli\u003epH measurement range: 0,00 - 14,00 pH\u003c\/li\u003e\n\u003cli\u003eMeasurement resolution: 0,01 pH\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 0,01 pH\u003c\/li\u003e\n\u003cli\u003eTemperature measuring range: 0,1 - 60,0 °C\u003c\/li\u003e\n\u003cli\u003eMeasurement resolution: 0,1 °C\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 0,5 °C\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 0 - 60 °C\u003c\/li\u003e\n\u003cli\u003eLiquid Temperature Compensation (ATC)\u003c\/li\u003e\n\u003cli\u003eCalibration: factory, electronic, two-point\/three-point\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eAll meters are ready for use (checked and calibrated before shipping)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eDimensions: 183mm X 37mm\u003c\/li\u003e\n\u003cli\u003eWeight: 88g meter (246g whole set)\u003c\/li\u003e\n\u003cli\u003ePower supply: 3 x 1,5V LR44 battery (set in meter and spare included)\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown function after 5 minutes of inactivity\u003c\/li\u003e\n\u003cli\u003eBrand new, calibrated product\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eElectronic pH tester with ATC function\u003c\/li\u003e\n\u003cli\u003eBuffer for calibration 4.01, 6.86 and 9,18 pH (for reconstitution with known pH)\u003c\/li\u003e\n\u003cli\u003ePlastic box\/case\u003c\/li\u003e\n\u003cli\u003eDetailed instruction in English\u003c\/li\u003e\n\u003cli\u003eDetailed instructions in Polish can be downloaded from the \"\u003cb\u003eAdditional information\"\u003c\/b\u003e tab located at the bottom of the page.\u003c\/li\u003e\n\u003c\/ul\u003e\u003col\u003e\n\u003cli\u003eBattery compartment cover\u003c\/li\u003e\n\u003cli\u003eIndicator battery level\u003c\/li\u003e\n\u003cli\u003epH display\u003c\/li\u003e\n\u003cli\u003eTemperature display\u003c\/li\u003e\n\u003cli\u003eOn button\u003c\/li\u003e\n\u003cli\u003eCalibration and change button °C\/°F\u003c\/li\u003e\n\u003cli\u003eMeasurement value stop button\u003c\/li\u003e\n\u003cli\u003eMaximum immersion level\u003c\/li\u003e\n\u003cli\u003eProtective cap of the measuring electrode\u003c\/li\u003e\n\u003cli\u003eMeasuring electrode\u003c\/li\u003e\n\u003c\/ol\u003e\u003cul\u003e\n\u003cli\u003eFishkeeping\u003c\/li\u003e\n\u003cli\u003egastronomy\u003c\/li\u003e\n\u003cli\u003eagriculture, forestry, water protection\u003c\/li\u003e\n\u003cli\u003egardening, hydroponics\u003c\/li\u003e\n\u003cli\u003ePools \u0026amp; Spas\u003c\/li\u003e\n\u003cli\u003efood industry\u003c\/li\u003e\n\u003cli\u003eChemical industry\u003c\/li\u003e\n\u003cli\u003edistilling and brewing\u003c\/li\u003e\n\u003cli\u003eph determination of water, urine, sewage, etc.\u003c\/li\u003e\n\u003cli\u003ewherever pH reagent measurement is needed\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eATC\u003c\/b\u003e function (\u003cb\u003eA\u003c\/b\u003eutomatic \u003cb\u003eT\u003c\/b\u003eemperature \u003cb\u003eC\u003c\/b\u003eompensation) - temperature measurement and compensation indication of the tester in the range of 0-60°C. Thanks to this, we obtain an accurate result of acidity of a given liquid.\u003c\/p\u003e\u003cp\u003eDue to the pH variability of the liquid relative to its temperature, only an acid meter with the \u003cb\u003eATC\u003c\/b\u003e function allows to obtain a reliable result consistent with the actual average value.\u003c\/p\u003e\u003cp\u003eThe pH tester complies with EU directives and is marked with the \u003cb\u003eCE\u003c\/b\u003e mark. In addition, the pH tester is made of materials that meet the strict requirements of the EU \u003cb\u003eROHS\u003c\/b\u003e directive.\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eMake 3 solutions with known pH using 250 ml of distilled water each and calibration buffers (4.01; 6.86; 9,18 pH included).\u003c\/li\u003e\n\u003cli\u003eDip the tester electrode into a solution with pH 6,86 (at 25℃) and wait for the reading to stabilize.\u003c\/li\u003e\n\u003cli\u003ePress the \"CAL\" button (calibration) for 5 seconds and release. The display will display a flashing \"CAL\" then flashing 6,86 when the calibration for this point stops flashing has been completed.\u003c\/li\u003e\n\u003cli\u003eClean the electrode in distilled water and dry.\u003c\/li\u003e\n\u003cli\u003eRepeat the procedure in sections 2 and 3 for solutions 4,01 and 9,18 pH.\u003c\/li\u003e\n\u003cli\u003eClean the electrode in distilled water and osusz.Umieść meter back in buffer solution to test calibration. If it is incorrect, repeat the calibration.\u003c\/li\u003e\n\u003c\/ol\u003e\u003col\u003e\n\u003cli\u003eRemove the protective cap. If crystals appear under it, this is not a cause for concern, this is normal with pH tester electrodes. The problem will disappear after rinsing the electrode with cleaning liquid\/water.\u003c\/li\u003e\n\u003cli\u003eTurn on the tester with the \"ON\/OFF\" button and immerse the pH meter electrode in the test liquid. Gently mix until the displayed value stabilizes, then read the value from the display.\u003c\/li\u003e\n\u003cli\u003eAfter the measurement, rinse the electrode with water and wipe with a cloth. Put on a protective cap\u003c\/li\u003e\n\u003c\/ol\u003e\u003cul\u003e\n\u003cli\u003eClean the electrode with distilled water each time before and after use.\u003c\/li\u003e\n\u003cli\u003eDo not touch the sensor electrode, as the oil on the skin can damage the sensor and affect the readings.\u003c\/li\u003e\n\u003cli\u003eStore the meter with a few drops of electrode storage fluid in the protective cap (e.g. GIB KCL or Growth Technology). Lack of this action may affect the correctness of readings and the life of the device.\u003c\/li\u003e\n\u003cli\u003eLarge differences in readings can be due to the need for calibration, a dry electrode or weak batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eRe-calibration is required for:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ebattery replacement,\u003c\/li\u003e\n\u003cli\u003every frequent measurements,\u003c\/li\u003e\n\u003cli\u003ethe display shows the message \"ERR\",\u003c\/li\u003e\n\u003cli\u003elong periods without measurements,\u003c\/li\u003e\n\u003cli\u003ethe need for very accurate measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTessa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eother (PH-03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003ePH-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5906660431350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eDominant color\u003c\/td\u003e\n\u003ctd\u003esilver\/gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003esynthetic material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eTotal capacity\u003c\/td\u003e\n\u003ctd\u003e100 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct height\u003c\/td\u003e\n\u003ctd\u003e18 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eNumber of cartridges included in the kit\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCartridge wear indicator\u003c\/td\u003e\n\u003ctd\u003enone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BIELASTO_S_C","offers":[{"title":"Default Title","offer_id":53202800083291,"sku":"8337018724","price":44.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/Electronic-pH-Meter-ATC-Tester-Autocalibration.jpg?v=1780231721","url":"https:\/\/homy.lt\/products\/elektroninis-ph-matuoklis-su-automatinio-kalibravimo-funkcija","provider":"homy.lt","version":"1.0","type":"link"}