{"product_id":"kompaktiskas-sieninis-rekuperatorius-awenta-hrv125-su-nuotoliniu-valdymu","title":"Kompaktiškas sieninis rekuperatorius Awenta HRV125 su nuotoliniu valdymu","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Kompaktiškas sieninis rekuperatorius Awenta HRV125 su nuotoliniu valdymu. Kategorija: Rekuperacinės vėdinimo sistemos.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Awenta\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e HRV125P\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe compact recuperator HRV125P\u003c\/b\u003e is designed for decentralized ventilation with heat recovery for use in one room in residential buildings.\u003c\/p\u003e \u003cp\u003eThe product is designed for continuous operation. It is equipped with an accumulative heat exchanger, whose task is to collect and render (recuperation) of thermal energy in the process of exhaust and air supply from the room in which it is installed.\u003c\/p\u003e\u003ch2\u003eTechnical data:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eType: Compact Wall Recuperator\u003c\/li\u003e \u003cli\u003eAdjustment: 2 gears, adjustable with infrared remote control\u003c\/li\u003e \u003cli\u003eCapacity: 50 \/ 70 m³\/h\u003c\/li\u003e \u003cli\u003eMotor speed: 2100 \/ 2500 rpm\u003c\/li\u003e \u003cli\u003eVolume: 37 \/ 42 dB\u003c\/li\u003e \u003cli\u003ePower: 3 \/ 4,5 W\u003c\/li\u003e \u003cli\u003ePower supply: 230V 50Hz\u003c\/li\u003e \u003cli\u003eDiameter: 125 mm\u003c\/li\u003e \u003cli\u003eInstallation: Through the wall\u003c\/li\u003e \u003cli\u003eDegree of protection: IPX4\u003c\/li\u003e \u003cli\u003eProducer: Awenta\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cb\u003eThe system operates in two modes: exhaust and air supply.\u003c\/b\u003e \u003cb\u003eEach mode can operate in two directions:\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003efree exhaust - free air supply\u003c\/li\u003e \u003cli\u003equick exhaust - fast air supply\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe duration of each mode is 60 seconds. Changing the gear is done by means of a two-position switch. Changing the position of the switch (fan operation) occurs by pulling the chain located on the front of the fan.\u003c\/p\u003e \u003ch2\u003eInstallation of the device\u003c\/h2\u003e \u003cp\u003eThe recuperator should be installed in the external partition \/ wall at an appropriate distance from sources of pollution (chimneys, exhaust gases, etc. ) so that the drawn – supplied air is free from contamination. Installation should begin with making a hole in the wall with a deviation of 2-5o from the level with a drop outside the room. The deviation is caused by the need to drain liquefied water. It is forbidden to mount the device in an upright position \"in the ceiling, roof\". The device does not require connection to the sewage system. The mounting height of the device is at least 2,3 m above the floor\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecuperation\u003c\/b\u003e gives you the opportunity to reduce heat losses caused by ventilation of the room. The task of the recuperator is therefore to recover heat from the air exhausted from the room in which it is installed. The HRV series device is equipped with an accumulative heat exchanger that stops and collects heat energy to transfer it to the supply air from the outside. Thanks to this solution, it is possible to exchange fresh air at a temperature similar to the temperature in the room.\u003c\/p\u003e \u003ch2\u003eExhaust mode\u003c\/h2\u003e \u003cp\u003eThe HRV recuperator is always started in exhaust mode. The air coming out of the room after turning it on gives heat energy to the aluminum exchanger. After sixty seconds, the fan automatically switches to airflow mode.\u003c\/p\u003e \u003ch2\u003eAir supply mode\u003c\/h2\u003e \u003cp\u003eThe air supplied from the outside - before it enters the room - is heated by the accumulated heat of the exchanger. Thanks to this action, the heat loss is not felt.\u003c\/p\u003e\u003ch2\u003eScheme of electrical connection:\u003c\/h2\u003e \u003cp\u003eConnection of power cables should be made with double or reinforced insulation in accordance with the Low Voltage LVD Directive. The installer with sep 1kV permissions is responsible for the proper connection of the device. The fan supply system shall be equipped with a circuit breaker in which the contact distance is at least 3 mm.\u003c\/p\u003e\u003cul\u003e \u003cli\u003e1 supply and exhaust fan\u003c\/li\u003e \u003cli\u003e2 fan grille\u003c\/li\u003e \u003cli\u003e3 screw fixing the power chamber cover\u003c\/li\u003e \u003cli\u003e4 power chamber cover\u003c\/li\u003e \u003cli\u003e5 Fan Mounting Screw Masking Caps\u003c\/li\u003e \u003cli\u003e6 pull chain for switching between the first and second fan gear (only in the version without remote control)\u003c\/li\u003e \u003cli\u003e7 telescopic ventilation duct for easy adjustment to the wall thickness of the room\u003c\/li\u003e \u003cli\u003e8 aluminum accumulation heat exchanger\u003c\/li\u003e \u003cli\u003e9 air filter\u003c\/li\u003e \u003cli\u003e10 external end of ventilation duct\u003c\/li\u003e \u003cli\u003e11 screw masking caps\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eDimensions:\u003c\/h2\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAwenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eheat recovery ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eHRV125P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eRange of energy efficiency classes\u003c\/td\u003e\n\u003ctd\u003eA+ - G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"budano_pl","offers":[{"title":"Default Title","offer_id":53909122515291,"sku":"18307264582","price":238.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/Compact-wall-recuperator-Awenta-HRV125-with-remote-control.jpg?v=1787925182","url":"https:\/\/homy.lt\/products\/kompaktiskas-sieninis-rekuperatorius-awenta-hrv125-su-nuotoliniu-valdymu","provider":"homy.lt","version":"1.0","type":"link"}