{"product_id":"rekuperatoriaus-valdiklis-zehnder-comfoair-basic","title":"Rekuperatoriaus valdiklis Zehnder ComfoAir Basic","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Rekuperatoriaus valdiklis Zehnder ComfoAir Basic. Kategorija: Dalys.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e IB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e IB-TRON 3100FAN 230V 5906268594686\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eATTENTION!\u003c\/b\u003e \u003cb\u003ePLEASE ONLY SUGGEST A DESCRIPTION IN THE CONTENT OF THE OFFER!\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eDue to the fact that in the process of productivization Allegro incorrectly combines offers with products, taking into account only a few parameters, please \u003cb\u003eSUGGEST ONLY THE DESCRIPTION IN THE CONTENT OF THE OFFER\u003c\/b\u003e and not the title of the product, which may be incorrect.\u003c\/p\u003e\u003cp\u003eUnfortunately, we have no influence on this and despite providing the correct parameters, Allegro incorrectly combines offers with products.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGeneral news\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eController \u003cb\u003eIB–Tron 3100FAN-230V \u003c\/b\u003eis an independent microprocessor controller equipped with a large liquid crystal LCD display, dedicated to operate air handling units. The controller allows you to control 3-speed control panels, for which the signal of switching on individual gears is short-circuiting the appropriate lines to lead out the common (for example, the mass of the system, neutral wire, etc.).\u003c\/p\u003e\u003cp\u003eThe \u003cb\u003eIB–Tron 3100FAN-230V \u003c\/b\u003e controller allows you to adjust the air exchange in the building based on a programmed work schedule or in manual mode.\u003c\/p\u003e\u003cp\u003eThe \u003cb\u003eIB–Tron 3100FAN-230V \u003c\/b\u003e controllers save energy costs by adjusting ventilation efficiency according to your needs. They thus contribute to environmental protection and financial savings. They can be widely used in hotels, offices, supermarkets, factories, hospitals, residential homes and other buildings.\u003c\/p\u003e\u003cp\u003e• does not contain impurities and residues from the fermentation process\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLarge backlit liquid crystal LCD display, displaying the current fan speed, temperature, settings, day of the week and other information.3 fan speed for your choice.\u003c\/li\u003e\n\u003cli\u003eInput for connecting the signal of the dirty filter of the ventilation unit. When this input is shorted to the neutral wire, the fan will be switched off as a priority and an audible signal will sound.\u003c\/li\u003e\n\u003cli\u003ePossibility to determine the passage of time, after which the control panel will switch to a mode reminding about the replacement of the filter (FILTER inscription, sound signal).\u003c\/li\u003e\n\u003cli\u003eAesthetic and modern look.\u003c\/li\u003e\n\u003cli\u003eBlue backlight of the screen (the backlight activates when you press any button and deactivates after some time of inactivity).\u003c\/li\u003e\n\u003cli\u003eEasy, intuitive operation and programming.\u003c\/li\u003e\n\u003cli\u003ePower supply from 230V mains with battery backup of settings memory.\u003c\/li\u003e\n\u003cli\u003eComprehensive programming of the process in a weekly cycle with an accuracy of 1 minutes and the ability to program 4 time periods each day.\u003c\/li\u003e\n\u003cli\u003eManual or automatic operation mode.\u003c\/li\u003e\n\u003cli\u003eTemperature displayed with a resolution of 0, 1°C.\u003c\/li\u003e\n\u003cli\u003eSupport additional digital input (three operating modes to choose from).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eCompatibility\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe controller can be installed in place of manual rotation switches, e.g.:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower supply: 230 V AC\u003c\/li\u003e\n\u003cli\u003eLegrand SISTENA LIFE Ventilation control switch 4 positions (0-1-2-3) 20A 250V cat. no. 775958.\u003c\/li\u003e\n\u003cli\u003eZehnder switch SA 1-3V ventilation 4 positions (0-1-2-3) 20A 250V cat. no. 775958.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe controller is compatible with the following recuperators, among others:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eZehnder ComfoAir 300, 350, 450, 550 Basic\u003c\/li\u003e\n\u003cli\u003eTitent B3B, ZWC-B\u003c\/li\u003e\n\u003cli\u003eStorkAir\u003c\/li\u003e\n\u003cli\u003eNED AIR WTA HR 300, 400\u003c\/li\u003e\n\u003cli\u003eAeris 350 Standard VV\u003c\/li\u003e\n\u003cli\u003eMistral 300, 400, 250 ECONO\u003c\/li\u003e\n\u003cli\u003eMistral Mini 250 (with AC 230V automatic)\u003c\/li\u003e\n\u003cli\u003eVasco D300EII, D400II, D400EPII, D500II, D500EII, DX4 E, DX5 E, DX6 E, X350, X425, X500, D275EP III\u003c\/li\u003e\n\u003cli\u003eHarmann Requra 20, 30, 40, 50\u003c\/li\u003e\n\u003cli\u003eITHO ECO4, HRU-3 BVH-004, Daalderop Aure Vent D250\u003c\/li\u003e\n\u003cli\u003eMitsubishi LGH Lossnay\u003c\/li\u003e\n\u003cli\u003eDospel Luna three-speed\u003c\/li\u003e\n\u003cli\u003eOrcon HRC EcoMax, MaxComfort 300, 400, 500\u003c\/li\u003e\n\u003cli\u003eCLIMA Xtract ECO Plus Flat\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe controller can also be connected directly to the fans:\u003c\/p\u003e\u003cp\u003eSingle-phase fans with gear control \"detachments\". Such a fan can be known by the fact that PE, N and several wires for the control phase leave it, e.g. L1, L2, L3.\u003c\/p\u003e\u003cp\u003eIf the fan has only three PE, N and L cables, it means that the fan is not factory adapted to change rotations. In order to control such a fan, additional electrical components are needed to control such a fan, e.g. inverter or autotransformer. An example of connection with such a fan using an autotransformer can be found in the user manual. On other offers we have elements necessary to connect such a fan.\u003c\/p\u003e\u003cp\u003eThree-phase fans - you need to design the appropriate connection depending on the fan used.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTechnical data\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower supply: 230 V AC\u003c\/li\u003e\n\u003cli\u003eMax. contact load:3A\/240V ? 700 IN\u003c\/li\u003e\n\u003cli\u003eGear signal: short circuit COM1\u003c\/li\u003e\n\u003cli\u003eFilter signal: short circuit with C 2\u003c\/li\u003e\n\u003cli\u003eDigital input: short circuit with C 2\u003c\/li\u003e\n\u003cli\u003eHousing: ABS\u003c\/li\u003e\n\u003cli\u003eDisplay: LCD (3,2”)\u003c\/li\u003e\n\u003cli\u003eControl: Electronic\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP30\u003c\/li\u003e\n\u003cli\u003eSettings memory: 36 months\u003c\/li\u003e\n\u003cli\u003eDimensions(height × width × depth):\u003c\/li\u003e\n\u003cli\u003eControl panel: 86 × 86 × 15 mm\u003c\/li\u003e\n\u003cli\u003eRelay module: 62 × 45 × 27 mm\u003c\/li\u003e\n\u003cli\u003ePower Consumption: \u0026lt; 2 W\u003c\/li\u003e\n\u003cli\u003eNumber of Gears: 3\u003c\/li\u003e\n\u003cli\u003eTemp. Storage: -5 ÷ 50°C\u003c\/li\u003e\n\u003cli\u003eTemp. displayed: -20 ÷ 140°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e--- \u003cb\u003eScope of delivery\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1x Controller (main panel)\u003c\/li\u003e\n\u003cli\u003e1x Relay Module\u003c\/li\u003e\n\u003cli\u003e1x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003ePrinciple of operation\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eWhen operating in automatic mode (with a schedule), the controller at the beginning of each time interval turns on the control panel gear programmed for this section. You can program 4 time intervals per day and assign each of them one of the 3 available speed values.\u003c\/p\u003e\u003cp\u003eIn manual mode, the user himself sets the course of the control panel. The control panel works on this gear all the time until another gear is set or the controller is turned off.\u003c\/p\u003e\u003cp\u003eAll gear control outputs are disconnected from the common output when the controller is off.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction of the controller\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe IB-Tron 3100FAN 230V controller consists of two parts: a main panel with LCD display and keyboard and a relay module, with a screw connector for connecting the air handling unit, an additional button, filter signal and power supply.\u003c\/p\u003e\u003cp\u003eBoth modules are connected to each other using a 7-wire cable, with a length of several centimeters.\u003c\/p\u003e\u003cp\u003e\u003cb\u003ememory capacity:\u003c\/b\u003e 256 MB\u003c\/p\u003e\u003cp\u003e\u003cb\u003eControl panel of the controller\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1 - Display\u003c\/li\u003e\n\u003cli\u003e2 - \u003cb\u003eM\u003c\/b\u003e button\u003c\/li\u003e\n\u003cli\u003e3 - \u003cb\u003eP\u003c\/b\u003e button\u003c\/li\u003e\n\u003cli\u003e4 - Temperature sensor\u003c\/li\u003e\n\u003cli\u003e5 - \u003cb\u003eMOUNTAIN\u003c\/b\u003e button\u003c\/li\u003e\n\u003cli\u003e6 - \u003cb\u003eDOWN\u003c\/b\u003e button\u003c\/li\u003e\n\u003cli\u003e7 - \u003cb\u003eFAN\/OK\u003c\/b\u003e button\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eLCD display\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1 - day of the week\u003c\/li\u003e\n\u003cli\u003e2 - current run or information\u003c\/li\u003e\n\u003cli\u003e3 - visible symbol means keyboard lock\u003c\/li\u003e\n\u003cli\u003e4 - temperature or setting value\u003c\/li\u003e\n\u003cli\u003e5 - visible symbol indicates active ventilation mode\u003c\/li\u003e\n\u003cli\u003e6 - graphic representation of the current race\u003c\/li\u003e\n\u003cli\u003e7 - visible symbol means manual mode\u003c\/li\u003e\n\u003cli\u003e8 - hour\u003c\/li\u003e\n\u003cli\u003e9 - working range\u003c\/li\u003e\n\u003cli\u003e10 - visible symbol means active semi-automatic mode\u003c\/li\u003e\n\u003cli\u003e11 - graphic representation of the current race. The animated fan rotates at different speeds or is not visible.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eInstallation\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eSeparate the two parts of the main panel housing of the controller. To do this, slide the flat screwdriver into the two slots visible at the bottom of the panel and pry the plastic hooks.\u003c\/p\u003e\u003cp\u003eAfter prying the hooks, carefully separate both halves of the main panel. To avoid damage to the housing, the separation should start from the bottom of the panel (from the side of the hooks).\u003c\/p\u003e\u003cp\u003eAfter separating both parts, disconnect the ribbon wire connecting the main panel to the actuator module by pulling the plug out of the outlet in the front of the panel.\u003c\/p\u003e\u003cp\u003eThe driver wiring, supplied to the electrical installation box, must be connected to the appropriate controller terminals, according to the instructions. Connection should be made with the power off.\u003c\/p\u003e\u003cp\u003eCarefully arrange the excess wires in the electrical installation box, avoiding stresses that can tear the wires out of the terminals.\u003c\/p\u003e\u003cp\u003ePlace the controller actuator module in the electrical installation box, and screw the back of the main panel housing with two screws.\u003c\/p\u003e\u003cp\u003eConnect the ribbon cable to the outlet in front of the main panel.\u003c\/p\u003e\u003cp\u003eConnect both parts of the controller, starting with hooks at the top of the device and ending with hooks at the bottom.\u003c\/p\u003e\u003cp\u003eFor flush-mounted installation, it is recommended to use a rectangular mounting can with dimensions of 80x80x50mm.\u003c\/p\u003e\u003cp\u003eThe box is available at a separate auction.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRelay module\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eL - power supply phase 230 V AC.\u003c\/li\u003e\n\u003cli\u003eN - neutral cable 230 V AC.\u003c\/li\u003e\n\u003cli\u003eHI - output of the 3 gear. This output is shorted to the common output when the controller wants to turn on the 3 gear of the control panel.\u003c\/li\u003e\n\u003cli\u003eMED - gear output 2. This output is shorted to the common output when the controller wants to turn on the 2 gear of the control panel.\u003c\/li\u003e\n\u003cli\u003eLO - output of gear 1. This output is shorted to the common output when the controller wants to turn on the 1 gear of the control panel.\u003c\/li\u003e\n\u003cli\u003eCOM1 - joint gear outlet.\u003c\/li\u003e\n\u003cli\u003eSI - input of the clogged filter signal. Short-circuiting this input to C 2 triggers an alarm.\u003c\/li\u003e\n\u003cli\u003eFAN - digital input. Short-circuiting this input to C 2 activates the input.\u003c\/li\u003e\n\u003cli\u003eC2 - AI and FAN common output.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe described short-circuit situation of HI, MED, LO to COM1 relays concerns a situation when the setting parameter CFG=4. A detailed description of other relay states for other CFG value settings is described later in the manual.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDigital FAN Input\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe controller is equipped with an additional digital FAN input where we can connect e.g. carbon monoxide, carbon dioxide, gas or air quality sensor (must have a NO connector). The active signal for this input is the short circuit of the FAN output from the C2. Typically, a monostable button is connected to this input (so-called. “bell”), shorted at the time of pressing and returning to the open position after releasing the button (used, for example, at doorbells). Alternatively, one of the FAN input modes provides for the connection of a bistable circuit breaker (standard, on\/off type), e.g. for lighting). depending on the selected function (description later in the manual), the controller changes the fan gear accordingly after shorting the digital input (pressing the button).\u003c\/p\u003e\u003cp\u003e\u003cb\u003eUser manual:\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eDetailed instruction manual in Polish:\u003c\/p\u003e\u003cp\u003ehttp:\/\/download.insbud.net\/pl\/manuals\/noname\/pl_ib-tron_3100fan-230v-noname.pdf\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eother\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eIB-TRON 3100FAN 230V 5906268594686\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"insbud_net","offers":[{"title":"Default Title","offer_id":53908701053275,"sku":"15241725912","price":108.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/Zehnder-ComfoAir-Basic-recuperator-controller.jpg?v=1787923877","url":"https:\/\/homy.lt\/products\/rekuperatoriaus-valdiklis-zehnder-comfoair-basic","provider":"homy.lt","version":"1.0","type":"link"}