{"product_id":"ritininiu-zaliuziu-valdiklis-elmes-st100hs-230v-su-imtuvu-ir-2-dwb100ht-pulteliais","title":"Ritininių žaliuzių valdiklis ELMES ST100HS, 230V, su imtuvu ir 2 DWB100HT pulteliais","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Ritininių žaliuzių valdiklis ELMES ST100HS, 230V, su imtuvu ir 2 DWB100HT pulteliais. Kategorija: Išoriniai moduliai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Elmes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e ST100HS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eST100HS - ELMES\u003c\/b\u003e - (receiver + 2x DWB100HT remote control)\u003c\/p\u003e\u003cp\u003eThe controller is designed for remote control of the roller shutter or gate and other devices,\u003c\/p\u003e\u003cp\u003ein which a single-phase alternating current motor 230V is used to work in two directions.\u003c\/p\u003e\u003cp\u003eThe motor should be equipped with limit switches.\u003c\/p\u003e\u003cp\u003eThe manual and programming of the controller is described in the paper manual in Polish and on the manufacturer’s website ELMES.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDriver functions\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eKEELOQ® variable code from Microchip Technology Inc. The USA providing a high level of security,\u003c\/li\u003e\n\u003cli\u003ecooperation with 1 or 2 remote control buttons – selected jumper JP1,\u003c\/li\u003e\n\u003cli\u003ecooperation with all pilots of Elmes Elektronik production on the 433,92 MHz band,\u003c\/li\u003e\n\u003cli\u003ewired control by means of monostable circuit breakers (so-called. bells);\u003c\/li\u003e\n\u003cli\u003econtrol of an external lamp performing a warning or lighting function – selected with a jumper JP2,\u003c\/li\u003e\n\u003cli\u003eautomatic closing after the programmed PAUSE time (1sec 4min) – selected with a jumper JP3,\u003c\/li\u003e\n\u003cli\u003eprogrammable engine operating time in the range: 1s - 4minutes,\u003c\/li\u003e\n\u003cli\u003eterminals for connecting a photocell (powering a photocell from a separate power supply),\u003c\/li\u003e\n\u003cli\u003estopping and then opening the roller shutter\/gate after the photocell is activated during closing,\u003c\/li\u003e\n\u003cli\u003eprolonging the PAUSE time when the photocell works.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMethod of action\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eDepending on the JP1 jumper setting, the controller works with 1 or 2 remote control buttons as follows:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ejumper JP1 compact – cooperation with 2 remote control buttons, one button switches the controller in the OPEN-STOP cycle..., and the other – CLOSING-STOP-CLOSING...\u003c\/li\u003e\n\u003cli\u003ejumper JP1 open - cooperation with 1 remote control button in the cycle OPENING-STOP-CLOSING-STOP...\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eWhen the engine is turned on, it is turned off:\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003ea) after pressing the remote control button or wired switch again,\u003c\/p\u003e\u003cp\u003eb) after the limit switch connected in series with the motor has been activated,\u003c\/p\u003e\u003cp\u003ec) after the programmed time (1s - 4 min),\u003c\/p\u003e\u003cp\u003ed) after the photocell is activated (only during closing).\u003c\/p\u003e\u003cp\u003eIf the photocell is activated during the closing of the gate, it will stop, and after 1s it will be opened.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eGate self-closing function selected by jumper JP3:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ejumper JP3 compact – self-closing gate disabled,\u003c\/li\u003e\n\u003cli\u003ejumper JP3 open - self-closing of the gate enabled - after the gate is fully opened, the PAUSE time is counted down, after which the gate closes automatically. Using the remote during the PAUSE closes the gate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe action of the photocell during the PAUSE prolongs its duration.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe lamp connected to the controller can perform two functions:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003elighting (JP2 jumper compact) – shines with continuous light during the movement of the gate and for the programmed time after stopping (this is the time equal to PAUSE).\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003ewarning (JP2 jumper open) – pulsates slower during opening and PAUSE, faster during closing,\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eATTENTION! The controller is powered from a 230V mains.\u003c\/p\u003e\u003cp\u003eInstallation can only take place with the mains voltage off.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDescription of connection terminals (for network potential):\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eL - terminal of the 230V mains power supply PHASE cable,\u003c\/p\u003e\u003cp\u003eN - 230V mains power supply zero cable terminal,\u003c\/p\u003e\u003cp\u003ePE - protective grounding of the network,\u003c\/p\u003e\u003cp\u003ePE - protective grounding of the engine,\u003c\/p\u003e\u003cp\u003eOPEN - engine phase clamp \/opening\/,\u003c\/p\u003e\u003cp\u003emiddle - zero motor cable,\u003c\/p\u003e\u003cp\u003eCLOSE - engine phase clamp \/closing\/,\u003c\/p\u003e\u003cul\u003e\u003cli\u003e- exit to the lamp,\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eDescription of connection terminals (currentless):\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eCOM - common terminal for circuit breakers and photocells,\u003c\/p\u003e\u003cp\u003eOP - wired switch – opening,\u003c\/p\u003e\u003cp\u003eCL - wired circuit breaker – closing,\u003c\/p\u003e\u003cp\u003eRS - signal from the photocell; if you do not install the photocell, the input is shorted from COM,\u003c\/p\u003e\u003cp\u003eThe controller should not be installed in places exposed to atmospheric factors.\u003c\/p\u003e\u003cp\u003eThe antenna of the controller is formed by a section of white wire with a length of 17cm.\u003c\/p\u003e\u003cp\u003eIn order to increase the operating range of remote controls, an external antenna can be connected to the receiver with a coaxial cable\u003c\/p\u003e\u003cp\u003erod or dipole directional, and disconnect the existing antenna wire.\u003c\/p\u003e\u003cp\u003eThe coaxial cable screen should be connected to the terminal: “⏚” of the antenna connector, and the middle cable (signal) to the terminal “A”.\u003c\/p\u003e\u003cp\u003eTwo 6 mm dowels are used to mount the controller to the wall.\u003c\/p\u003e\u003cp\u003eThe controller should be installed in such a way that the antenna cable hangs freely.\u003c\/p\u003e\u003cp\u003eThe antenna cable should not be permanently attached and glued to the walls.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTECHNICAL DATA:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003esuperheterodyne receiver 433,92MHz powered from 230VAC (2VA),\u003c\/li\u003e\n\u003cli\u003eroller shutter motor relay outputs: 2 x NO, max. 16A\/250VAC\u003c\/li\u003e\n\u003cli\u003eoutput to the lamp: max. 5A\/250VAC,\u003c\/li\u003e\n\u003cli\u003eentry to a photocell type NC (normally compact),\u003c\/li\u003e\n\u003cli\u003epilots' memory capacity: 112;\u003c\/li\u003e\n\u003cli\u003erelay outputs support time: 1 s - 4 min, common for closing and opening,\u003c\/li\u003e\n\u003cli\u003ePAUSE time: 1 s - 4 min,\u003c\/li\u003e\n\u003cli\u003eexternal dimensions (d\/s\/w) 87\/87\/39mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eDWB100HT - two-channel remote control - 2 pcs.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eKEELOQ® variable coding system\u003c\/p\u003e\u003cp\u003eAlarm transmissions are dynamically encoded in the KEELOQ® system from Microchip USA, ensuring the highest level of security.\u003c\/p\u003e\u003cp\u003eEach press of the remote control button generates and sends a new code.\u003c\/p\u003e\u003cp\u003eThe receiver tracks these changes and only responds to new code. \u003cb\u003eCodes once used are not accepted.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePrevents\u003c\/b\u003e from reusing captured codes.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eoperating frequency 433,92MHz;\u003c\/li\u003e\n\u003cli\u003epower 3-5mW;\u003c\/li\u003e\n\u003cli\u003erange in open area approx. 100m\u003c\/li\u003e\n\u003cli\u003eGP23A 12V battery - \u003cb\u003eincluded\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003edimensions (L\/W\/H) 50\/37\/14mm.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eALL\u003c\/b\u003e other \u003cb\u003eELMES \u003c\/b\u003e brand drivers and other products can be found in adjacent auctions.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eother\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eST100HS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eElmes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003emains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eAdditional features\u003c\/td\u003e\n\u003ctd\u003eradio communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eST100HS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEAN (GTIN)\u003c\/td\u003e\n\u003ctd\u003e5906770220066\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ALERTUS","offers":[{"title":"Default Title","offer_id":54077496623451,"sku":"12372206096","price":72.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/ST100HS-driver-for-1-roller-shutter-230VAC-RECEIVER-2x-DWB100HT-ELMES.jpg?v=1789559782","url":"https:\/\/homy.lt\/products\/ritininiu-zaliuziu-valdiklis-elmes-st100hs-230v-su-imtuvu-ir-2-dwb100ht-pulteliais","provider":"homy.lt","version":"1.0","type":"link"}