{"product_id":"silumos-siurblys-baseinui-hewalex-pcwbi-11-5-kw-c-inverteris-bajpasas","title":"Šilumos siurblys baseinui HEWALEX PCWBi 11,5 kW-C, inverteris, bajpasas","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Šilumos siurblys baseinui HEWALEX PCWBi 11,5 kW-C, inverteris, bajpasas. Kategorija: Siurbliai ir filtrai.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e Hewalex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e PCWBi 11.5kW-C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHeat pump for swimming pool\u003c\/h2\u003e\u003ch2\u003eHewalex 11,5 kW-C\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eINCLUDED:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHeat pump series PCWB\u003c\/li\u003e\n\u003cli\u003emWiFi module\u003c\/li\u003e\n\u003cli\u003eOperation and assembly manual\u003c\/li\u003e\n\u003cli\u003eUser manual for the mWiFi module\u003c\/li\u003e\n\u003cli\u003eWarranty card\u003c\/li\u003e\n\u003cli\u003eControl panel in housing\u003c\/li\u003e\n\u003cli\u003eO-ring seal - 2 pieces\u003c\/li\u003e\n\u003cli\u003eVibration Insulating Pad - 4 Pieces\u003c\/li\u003e\n\u003cli\u003eScrew for glued joints PVC-U 50mm, Gz 6\/4” - 2 pieces\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eYOU BUY FROM AN AUTHORIZED AND CERTIFIED DISTRIBUTOR\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eWe know perfectly well the differences between different brands that are noteworthy and have a long warranty. Test our knowledge and be sure that the model you choose will be suitable for your pool and temperature expectations.\u003c\/p\u003e\u003cp\u003eSupport and service in Poland – authorized service and availability of spare parts guarantee peace of mind.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRecommended water flow 4 m3\/h (3,1-7,5) adjustable bypass\u003c\/li\u003e\n\u003cli\u003eThe maximum free chlorine level is 1500mg Cl\/litre of water.\u003c\/li\u003e\n\u003cli\u003eThe maximum salinity of pool water is 10g NaCl\/litre of water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eEXTENDED BYPASS INCLUDED:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e1 - BAJPAS 50mm for self-assembly\u003c\/li\u003e\n\u003cli\u003e2 - tapered BUSHINGS for hose 32\/38 mm - 2x\u003c\/li\u003e\n\u003cli\u003e3 - Galvanized hose clamp band - 2x\u003c\/li\u003e\n\u003cli\u003e4 - GLUE with brush\u003c\/li\u003e\n\u003cli\u003e5 - TEFLON SEALING TAPE\u003c\/li\u003e\n\u003cli\u003e6 - Nuts for a typical pool hose\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eConnect pool hoses to the set\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003efor 32 and 38mm clamps\u003c\/li\u003e\n\u003cli\u003eon nuts of typical models\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eI n t e x \/ B e s t w a y\u003c\/p\u003e\u003ch2\u003eWe are not a construction market.\u003c\/h2\u003e\u003cp\u003eWe are certified specialists. For years, we have been advising customers on how to choose a heat pump so as not to overpay for electricity. We know perfectly well the differences between different brands that are noteworthy and have a long warranty. Test our knowledge and be sure that the model you choose will be suitable for your pool and temperature expectations. Be sure that the equipment is selected for your pool, not “by eye”.\u003c\/p\u003e\u003cp\u003e— Grzegorz Jasiński Owner and Chief Technical Expert\u003c\/p\u003e\u003ch2\u003eGREE - The Heart of Your Pool\u003c\/h2\u003e\u003cp\u003eDedicated inverter compressor \u003cb\u003eGree. \u003c\/b\u003e This is no ordinary device – it is an intelligent system that takes care of your comfort and wallet.\u003c\/p\u003e\u003ch2\u003eWhy is this solution better for you?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLiquidity, not \"Jumps\" (Scope 20 to 100%):\u003c\/b\u003e The Gree compressor acts as a gas pedal in a modern car – smoothly adjusts the power to the current water temperature. Once the pool is heated, the pump slows down, using only a fraction of the energy needed to maintain the heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh Lifespan:\u003c\/b\u003e By avoiding constant starting and stopping, components wear out much slower. It is a technology for years that guarantees reliability even under intensive use in the season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThe Gree compressor is two-rotation\u003c\/b\u003e, thanks to which it operates quieter and reduces mechanical vibrations, making the system work more efficiently.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIt must be taken into account that the pump power is given at a temperature of 27C degrees of air and 26C of water. As a rule, such an air temperature will last for a while, and most customers expect more than 26C of water temperature. Therefore, it is worth choosing a stronger pump so that it has a supply of energy so that it can go down to lower revolutions, and thus be more economical. She could have worked quieter. And do not walk all the time 100% but exploit less.\u003c\/p\u003e\u003ch2\u003eLatest 11.5 kW-C Series\u003c\/h2\u003e\u003cp\u003eWhen you buy \u003cb\u003efrom us, you get a pump from the latest distribution\u003c\/b\u003e. What distinguishes the 11.5kWc model is that the \u003cb\u003eGree compressor design is dual rotary.\u003c\/b\u003e This \u003cb\u003eeliminates vibrations\u003c\/b\u003e and makes the \u003cb\u003epump quieter\u003c\/b\u003e. Additionally, the \u003cb\u003efan is inverter-driven.\u003c\/b\u003e This makes the control more precise and energy-efficient than a standard on\/off fan and compressor.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWhat is the real power of the 11.5kWc pump?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe pump's operating power and COP (Coefficient of Performance) depend on the temperature. At an \u003cb\u003eair temperature of 27°C and a pool water temperature of 26°C\u003c\/b\u003e, the pump has \u003cb\u003e11.5 kWc\u003c\/b\u003e, and the COP reaches from 5.8 at 100% power to 10.2 when it operates at only 20%. This temperature is not common in Poland.\u003c\/p\u003e\u003cp\u003eWhen the air temperature drops, the pump's power decreases. At an \u003cb\u003eair temperature of 15°C, the maximum power is 8.5 kW\u003c\/b\u003e, and the COP reaches a value from 4.3 to 6.2.\u003c\/p\u003e\u003cp\u003eWhen the \u003cb\u003eair temperature drops to 10°C, the pump reaches a maximum power of 7.5 kW\u003c\/b\u003e, and its COP drops from 3.8 to 5. At this temperature, don't be surprised if the difference between the inlet and outlet is about 1°C. Therefore, using it at lower temperatures is not cost-effective.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTherefore, if you want to extend the swimming season, it's worth choosing a more powerful pump:\u003c\/b\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eIt will work more quietly because it will have a power reserve to run at lower speeds.\u003c\/li\u003e\n\u003cli\u003eAt lower speeds, it will wear out less because it won't be running at 100% power all the time, which will extend its lifespan.\u003c\/li\u003e\n\u003cli\u003eWhen the pump is not running at 100% but at lower speeds, the COP will increase because it will be working at lower speeds, so the energy bill will be lower. And at lower air temperatures in the evening, its power won't be as weak, and we'll have a pleasant temperature in the morning. Considering that the price difference is small, it's worth investing in a larger pump so you don't have to wait long for the pool to heat up and don't have to worry about whether the summer will be cold this year.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eInstallation and ongoing operation also without stress\u003c\/h2\u003e\u003cp\u003eInstallation of PCWBi heat pumps is a relatively easy and quick operation. The internal system is completely hermetic and does not require interference with installation work. They are run outside the building, usually by the pool itself. The controller itself does not need complicated configuration. To connect the pool water circuit, it will be best to use a bypass. It consists of piping and 3 valves to cut off the flow of water through the heat pump, as well as its regulation. The device can also be quickly disassembled and stored for the winter in a closed room.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConnection of pool hoses\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe kit makes it easy to connect hoses if you have a pool for \u003cb\u003e32mm or 38mm\u003c\/b\u003e clamps (white reductions in the photo) Just between the filter pump and the pool overload the pool hose and insert the heat pump in this place. The closer we put the heat pump, the lower the temperature losses on the hoses. We can also mount on bypass\u003cb\u003e hose on nuts\u003c\/b\u003e, the so-called nipples that can be seen applied to the bypass on the right side, this is a very common solution and at the same time the simplest if we want to keep nuts. Although, when we cut a 32mm or 38 hose, we can buy fittings so that we can reconnect the average hose.\u003c\/p\u003e\u003ch2\u003eFUNCTIONAL CONTROLLER WITH BLUETOOTH\u003c\/h2\u003e\u003cp\u003eFunctional, easy-to-use controller with touch screen, heating\/cooling temperature setting and operating times. With the mWiFi module, it is possible to control and preview work using a mobile application. The pumps we have come from the latest delivery, they have a built-in Bluetooth module\u003c\/p\u003e\u003cp\u003e\u003cb\u003eCONTROL OF THE FILTER PUMP\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe heat pump controller also allows you to program two time intervals, operating regardless of the settings of the heat pump, in which it is possible to filter the pool.\u003c\/p\u003e\u003ch2\u003eComfort among the sounds of nature\u003c\/h2\u003e\u003cp\u003eThe biggest advantage of the Gree inverter is the work culture. At lower loads, the compressor operates almost silently. Thanks to this, relaxation in the pool or rest on the terrace takes place in absolute peace, without the cumbersome hum known from older devices.\u003c\/p\u003e\u003cp\u003ePool heat pumps PCWBi-C thanks to the use of an inverter compressor, work with previously unattainable minimum volume level. The level of 38 dB(A) at a distance of 1 meter, achieved with the smoothly reduced efficiency of the heat pump means that when relaxing in the garden, we will primarily hear louder birdsong. So for the highest demands, when the house is in an extremely quiet area, the choice of the PCWBi-C heat pump will have additional justification.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSound pressure level (1m):\u003c\/b\u003e is \u003cb\u003e38 ~ 48 dB(A)\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAcoustic power level:\u003c\/b\u003e is \u003cb\u003e51,8 ~ 61,8 dB(A)\u003c\/b\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eFor comparison (view scale):\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e31 dB(A):\u003c\/b\u003e Very quiet street without traffic, whisper up close.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e51 dB(A):\u003c\/b\u003e Office noise, normal conversation, moderate rain.\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eFor comparison (view scale):\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith the mWiFi module, it is possible to control and preview work using the Aqua Temp smartphone application is a remote control over the pool installation.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe mWiFi PCWB module allows you to perform functions such as m.in.:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eturning the heat pump on and off\u003c\/li\u003e\n\u003cli\u003esetting of heat pump operating times\u003c\/li\u003e\n\u003cli\u003echoice of heat pump operating mode: heating\/cooling\/automatically\u003c\/li\u003e\n\u003cli\u003esetting the required water temperature in the pool\u003c\/li\u003e\n\u003cli\u003eMonthly statistics of changes in water temperature in the pool\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003eCurrent weather and weather forecast for 3 days\u003c\/li\u003e\n\u003cli\u003esetting the pump operating time\u003c\/li\u003e\n\u003cli\u003enotification of critical errors in the operation of the device\u003c\/li\u003e\n\u003cli\u003etemperature chart of the last 7 days\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eWe offer the latest pumps that have been equipped with a Bluetooth module!\u003c\/b\u003e\u003c\/p\u003e\u003ch2\u003eTITANIUM STEEL HEAT EXCHANGER\u003c\/h2\u003e\u003cp\u003eThe special design of the heat exchanger and condenser, made of titanium steel, ensures resistance to pool water.\u003c\/p\u003e\u003cp\u003eThe design of the titanium heat exchanger significantly increases efficiency and provides sufficient heating power; the heat exchanger is made of high-quality titanium steel and PVC material, resistant to the chemistry used for water treatment in swimming pools\u003c\/p\u003e\u003cp\u003eThe shell-tube exchanger is also a heat pump condenser, which ensures high heat transfer efficiency. Pool water is located in the mantle part with low flow resistance, and the refrigerant flows through a coil with a developed heat dissipation surface. The coil is reinforced with handles for protection against vibrations and turbulence of flowing pool water. The resistance of the exchanger to the chemical impact of pool water is ensured by the materials used in the construction of the exchanger - titanium steel and PVC material.\u003c\/p\u003e\u003ch2\u003ePROTECTION OF THE HEAT PUMP AGAINST FREEZING\u003c\/h2\u003e\u003cp\u003eThe people on the evaporator cause disruption and decrease air flow, which in turn results in less free heat consumption and more compressor operation. Defrosting depends on the indications of the temperature sensor placed on the evaporator.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAUTOMATIC DEFROSTING\u003c\/li\u003e\n\u003cli\u003eEVAPORATOR DEFROSTING MODE\u003c\/li\u003e\n\u003cli\u003eFUNCTION OF PROTECTING THE HEAT PUMP FROM FREEZING\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe pump has a water cooling function in the pool if necessary.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFirst degree of antifreeze protection:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe protection will be activated when the water outlet temperature from the heat pump reaches between 2 and 4°C and the ambient temperature will be lower than 0°C. The E19 code will be displayed on the screen. At this point, a filter pump will be started, which will work until the water temperature reaches a minimum of 8°C or until the ambient temperature rises above 1°C. The device will then return to standby mode.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSecond degree of antifreeze protection:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe protection will be activated when the water outlet temperature from the heat pump is lower than 2 °C and the ambient temperature is lower than 0°C. The E29 code will be displayed on the screen. At this point, the heat pump will be started in heating mode. The device in heating mode will work until it reaches a water temperature of at least 15°C or until the ambient temperature rises above 1°C. The device will then return to standby mode.\u003c\/p\u003e\u003ch2\u003eWhat is COP?\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eCOP\u003c\/b\u003e (Coefficient of Performance) is a \u003cb\u003eperformance factor\u003c\/b\u003e that determines the relationship between free energy given into the pool and paid electricity taken from the grid.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePrinciple of operation:\u003c\/b\u003e If the pump has \u003cb\u003eCOP = 5\u003c\/b\u003e, then with \u003cb\u003e1 kWh\u003c\/b\u003e of current generates \u003cb\u003e5 kWh\u003c\/b\u003e of heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMain advantage:\u003c\/b\u003e The higher the ratio, the lower the water heating bills.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVariability:\u003c\/b\u003e COP is not constant – it increases when it is warmer outside, and when the pump (inverter) is running at lower speeds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003ePerformance of the 11,5 kW-C:\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eAccording to the technical parameters, this model is characterized by extremely high efficiency:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum COP: 10,4\u003c\/b\u003e – occurs under ideal conditions (air 27∘C) when the pump after heating the pool goes into the mode of maintaining the temperature at the lowest speed (approx. 20% power). Then over \u003cb\u003e90% of energy\u003c\/b\u003e is completely free.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCOP in Polish conditions (A15°C\/W26°C):\u003c\/b\u003e On a typical Polish summer day, at an air temperature of 15∘C, the COP for this model ranges from \u003cb\u003e4,3 to 6,2\u003c\/b\u003e. This means that even with a cooler aura, you still gain 4 to 6 times more energy than you consume.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eWhy is COP changing?\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIt is worth remembering that COP is not a constant value. It depends on two factors:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eAmbient temperature:\u003c\/b\u003e The warmer the air, the easier it is for the pump to \"pull\" heat out of it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInverter operation:\u003c\/b\u003e The Hewalex pumps of the PCWBi series are inverter devices. They achieve the highest efficiency not when they work \"on full gas\", but when they calmly maintain the set temperature.\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cb\u003eNote\u003c\/b\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eManufacturers always give the pump power at an air temperature of 27C (sometimes different), and this does not happen often. So its power is not really what they color.\u003c\/li\u003e\n\u003cli\u003eCop is often a marketing ploy, because it is given at 27C air temperature, and additionally, when the pump already heats the pool and only maintains the water temperature 26C at 27C air temperature\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eThe choice of PCWBi pump is the absence of hidden operating costs:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNo paid inspections:\u003c\/b\u003e The current generation of Hewalex pumps does not require mandatory, paid service inspections, which distinguishes it from many competitive solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEcological refrigerant R32:\u003c\/b\u003e The use of modern refrigerant R32 (0,46 kg) provides higher energy efficiency with less environmental impact (GWP only 675).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecial Solutions in the PCWBi Heat Pump Construction\u003c\/h2\u003e\u003cp\u003eThe PCWB heat pump is specifically adapted to work for heating pool water. It uses \u003cb\u003emodern, quiet rotary compressors.\u003c\/b\u003e The shell-and-tube heat exchanger built into the heat pump has a special design, where the refrigerant transfers heat directly to the flowing pool water. \u003cb\u003eProtection of the heat pump\u003c\/b\u003e against a possible loss of water flow is provided by a \u003cb\u003ebuilt-in SIKA flow sensor.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eController resistant to external conditions\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIt is built on a heat pump. The settings include m.in.:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eoperating mode selection: AUTOMATIC \/ HEATING \/ COOLING\u003c\/li\u003e\n\u003cli\u003eworking time intervals, e.g. for 2-zone energy purchase tariffs\u003c\/li\u003e\n\u003cli\u003esetting the required pool water temperature\u003c\/li\u003e\n\u003cli\u003ealarm states, e.g. lack of water flow\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eCONTROL OF THE FILTER PUMP\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe heat pump controller also allows you to program two time intervals, operating regardless of the settings of the heat pump, in which it is possible to filter the pool. To activate the function, set the value of parameter P05 to 1, see. Chapter 9.1 in the instructions at the bottom of the listing.\u003c\/p\u003e\u003cp\u003eThen set the on (P06) and off (P07) time of the first pool filtration time program. The same should be done for the second time program (P08 and P09). Operation of the filter pump in the above time intervals will be in accordance with the setting of the parameter P01\u003c\/p\u003e\u003cp\u003e\u003cb\u003eInstallation diagram with heat pump type PCWBi\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eIn most cases, the use of a PCWBi heat pump requires minimal interference in the pool water circuit. The materials used and the design of the heat exchanger (condenser) allows direct flow of water through the heat pump. Low condenser flow resistance in most cases allows you to use the existing circulation pump. The heat pump is incorporated into the pool water circuit behind the filtration devices and in front of the chemical dispenser.\u003c\/p\u003e\u003cp\u003eInstructions to download below the auction in the additional information tab.\u003c\/p\u003e\u003ch2\u003eSPECIFICATIONS HEWALEX PCWBi 11,5kW-C\u003c\/h2\u003e\u003cp\u003e\u003cb\u003eHeating efficiency (A27°C air \/ W26°C water):\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHeating power:\u003c\/b\u003e 2,6 – 11,5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectric power:\u003c\/b\u003e 0,25 – 1,92 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCOP:\u003c\/b\u003e 6,0 – 10,4\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eHeating mode performance (A15°C \/ W26°C):\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHeating power:\u003c\/b\u003e 1,5 – 8,5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectric power:\u003c\/b\u003e 0,24 – 1,97 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCOP:\u003c\/b\u003e 4,3 – 6,2\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eHeating efficiency (A10°C \/ W26°C):\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHeating power:\u003c\/b\u003e 1,7 – 7,5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectric power:\u003c\/b\u003e 0,33 – 1,97 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCOP:\u003c\/b\u003e 3,8 – 5,0\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eElectrical and operational parameters:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePower supply:\u003c\/b\u003e 230V~ \/ 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum electrical power:\u003c\/b\u003e 2,35 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum current:\u003c\/b\u003e 11,5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompressor type:\u003c\/b\u003e Gree rotary inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFan:\u003c\/b\u003e 40 W \/ 1 pc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAir flow:\u003c\/b\u003e 2300 m³\/h\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003ePlumbing and cooling:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eRecommended water flow:\u003c\/b\u003e 4,7 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWater flow range (min\/max):\u003c\/b\u003e 2,8 \/ 7,0 m³\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWater connections:\u003c\/b\u003e GW 6\/4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum pressure drop:\u003c\/b\u003e 2,7 kPa\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRefrigerant \/ quantity:\u003c\/b\u003e R32 \/ 0,45 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGWP \/ tonne of CO2 equivalent:\u003c\/b\u003e 675 \/ 0,304\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eAcoustics (Volume):\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSound pressure level (1m):\u003c\/b\u003e is \u003cb\u003e38 ~ 48 dB(A)\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAcoustic power level:\u003c\/b\u003e is \u003cb\u003e51,8 ~ 61,8 dB(A)\u003c\/b\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eDimensions and weight:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNet \/ gross weight:\u003c\/b\u003e 44 \/ 54 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions of the device (length\u003c\/b\u003e \u003cb\u003ex D.\u003c\/b\u003e \u003cb\u003ex H\u003c\/b\u003e \u003cb\u003e):\u003c\/b\u003e 933,5 x 360 x 610 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackage dimensions (L\u003c\/b\u003e \u003cb\u003ex D.\u003c\/b\u003e \u003cb\u003ex H\u003c\/b\u003e \u003cb\u003e):\u003c\/b\u003e 970 x 410 x 630 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eAdditional information:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHeat exchanger:\u003c\/b\u003e Made of titanium steel and PVC (resistant to pool chemistry).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eReviews:\u003c\/b\u003e No paid mandatory reviews required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCooling mode:\u003c\/b\u003e Possibility to set the water outlet temperature at 8°C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e*The upper capacity limits apply to the indoor pool and very well insulated, with the warmest water.\u003c\/p\u003e\u003cp\u003e*Data according to EN 14511 for operating point A27\/W26 (air at input 27°C, water at output 26°C).\u003c\/p\u003e\u003cp\u003e**Data for air at 20°C input and water at 26°C output\u003c\/p\u003e\u003cp\u003e\u003cb\u003eRecommended flow rate 3,2 m3\/h (2,8-7m3\/h)\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe maximum free chlorine level is 1500mg Cl\/litre of water.\u003c\/p\u003e\u003cp\u003eThe maximum salinity of pool water is 10g NaCl\/litre of water.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eInstructions for assembly can be found under the description of the auction\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eTemperature Regulation:\u003c\/b\u003e The maximum outlet water temperature is typically less than \u003cb\u003e40°C.\u003c\/b\u003e The fact that you can set 40°C on the display does not necessarily mean it will be reached, as it depends on the insulation and capacity of the pool. The high pool volume stated by the manufacturer applies to low water heating temperatures, only in warm weather. In other words, \u003cb\u003efor 50m3 of water, 13kW is not recommended; a minimum of 17.5 kW-B is needed. Customers buy 13.2kWc for pools of 20m3 and smaller. This is because frame pools are cooled by wind and low evening temperatures and do not have thermal insulation like indoor pools. The use of a solar cover is required.\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eOperating at the highest speeds shortens the life of the compressor and causes more noise. \u003cb\u003eBy oversizing the pump, the compressor runs quieter and at lower speeds, consuming less electricity.\u003c\/b\u003e So, if you're wondering whether to oversize the pump, the answer is yes, it's worth it. For example, \u003cb\u003ein winter, for covered pools or indoors, it is recommended to oversize the pump by 3x\u003c\/b\u003e, and even then, the pool is additionally supported by a heater or heat exchanger.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eWhat to Consider\u003c\/h2\u003e\u003cp\u003eHeat pumps from the manufacturer are not factory-equipped with a power cord; you need to purchase a 3×2.5 mm2 cord separately.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eCHOOSING THE INSTALLATION LOCATION to ensure the heat pump operates with the highest efficiency and declared heating power\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eDo not install the unit in places with limited air access, where exhaust air recirculation would occur.\u003c\/p\u003e\u003cp\u003eDo not install near plants that could block airflow. Cold air can harm plants.\u003c\/p\u003e\u003cp\u003eThe location must continuously ensure free access to fresh and clean air and the flow of pool water. A pump in a closed room will frost up and turn it into a cold room.\u003c\/p\u003e\u003cp\u003eDo not place the pump where there is a draft, as it will not effectively collect heat from the air.\u003c\/p\u003e\u003cp\u003eDetailed information and operating instructions - download the product card below:\u003c\/p\u003e\u003cp\u003eThe bypass should be cut and glued so that it fits the spacing in the pump. It will arrive separately by courier; the pallet with the pump is shipped on a pallet for safety reasons.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eChemicals: chlorine \/ salt\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe maximum level of free chlorine is 1500mg Cl\/liter of water.\u003c\/li\u003e\n\u003cli\u003eThe maximum salinity of pool water is 10g NaCl\/liter of water.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCall me to get a pump for the pool.\u003c\/h2\u003e\u003ch2\u003eSee all pump parameters and download the instructions below by clicking the product card:\u003c\/h2\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHewalex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003ePCWBi 11.5kW-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eProduct weight with unit packaging\u003c\/td\u003e\n\u003ctd\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003ePackaging status\u003c\/td\u003e\n\u003ctd\u003eoriginal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"_pompy_ciepla_","offers":[{"title":"Default Title","offer_id":53521357865307,"sku":"17327609604","price":1531.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/HEWALEX-PCWBi-11-5-kW-C-HEAT-PUMP-FOR-SWIMMING-POOL-11-5kwc-INVERTER-BAJPAS.jpg?v=1783349544","url":"https:\/\/homy.lt\/products\/silumos-siurblys-baseinui-hewalex-pcwbi-11-5-kw-c-inverteris-bajpasas","provider":"homy.lt","version":"1.0","type":"link"}