{"product_id":"vedinimo-irenginys-su-rekuperatoriumi-podw-ec-300-m-val","title":"Vėdinimo įrenginys su rekuperatoriumi PODW EC, 300 m³\/val.","description":"\u003ch2\u003eTrumpai apie prekę\u003c\/h2\u003e\u003cp\u003ePrekė: Vėdinimo įrenginys su rekuperatoriumi PODW EC, 300 m³\/val.. Kategorija: Rekuperacinės vėdinimo sistemos.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGamintojas:\u003c\/strong\u003e no brand\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModelis:\u003c\/strong\u003e A-300 PODWIESZANA EC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e15 years of experience\u003c\/p\u003e\u003cp\u003e\u003cb\u003eThe headquarters meets the requirements of WFOŚiGW regarding the Clean Air program.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eBefore you buy, watch the video https:\/\/www.youtube.com\/watch?v=m8BvSsrRX5w\u003c\/p\u003e\u003cp\u003ePOSSIBILITY OF CONNECTING AIR CONDITIONING (very effective if you make a recirculation system \"at home works as an air conditioner in summer and in winter as heating -it is effective up to -2c outdoors\" )\u003c\/p\u003e\u003cp\u003e\u003cb\u003eBuilt-in negative ionizer\u003c\/b\u003e\u003c\/p\u003e\u003ch2\u003eNegative ion helps:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKill bacteria, viruses and fungi\u003c\/li\u003e\n\u003cli\u003eFacilitates breathing\u003c\/li\u003e\n\u003cli\u003eClean and refresh the air\u003c\/li\u003e\n\u003cli\u003eAccelerate rest\u003c\/li\u003e\n\u003cli\u003eIncreases concentration\u003c\/li\u003e\n\u003cli\u003eHelps in learning\u003c\/li\u003e\n\u003cli\u003eImproves fitness\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eContains:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFAN \"EC\" WITH MAX CAPACITY UP TO 800m3\/h Taiwanese company proven fans (this fan manufacturer is found in almost every air conditioning in Europe)\u003c\/li\u003e\n\u003cli\u003eBUILT-IN IONIZER\u003c\/li\u003e\n\u003cli\u003eDIAMETER OF THE STUB 200 mm\u003c\/li\u003e\n\u003cli\u003eRPM MAX 2400 rpm\u003c\/li\u003e\n\u003cli\u003eCLASS G4 FILTERS\u003c\/li\u003e\n\u003cli\u003eCOUNTERCURRENT RECUPERATOR PULL-OUT EASY TO WASH\u003c\/li\u003e\n\u003cli\u003eRECUPERATOR EFFICIENCY FROM 65% to 92% (parameter depends on the difference in flow rate)\u003c\/li\u003e\n\u003cli\u003ePOWER OF THE DEVICE FROM 25 TO 200W\u003c\/li\u003e\n\u003cli\u003eBUILT-IN AIR PURIFIER SYSTEM (MICRO PARTICLES)\u003c\/li\u003e\n\u003cli\u003eANTI-ELECTROSTATIC SYSTEM\u003c\/li\u003e\n\u003cli\u003eDIRTY FILTER INFORMATION SYSTEM\u003c\/li\u003e\n\u003cli\u003eBY-PASS ELECTRONIC\u003c\/li\u003e\n\u003cli\u003eHOUSING MADE OF SHEET METAL 0,7 mm ALUM-ZINC\u003c\/li\u003e\n\u003cli\u003eINSULATION THICKNESS 30 mm=3cm\u003c\/li\u003e\n\u003cli\u003eSOUND INSULATION\u003c\/li\u003e\n\u003cli\u003eFIREPLACE THERMAL INSULATION RESISTANT TO HIGH TEMPERATURES. WITH ALUMINIUM JACKET\u003c\/li\u003e\n\u003cli\u003eDRAINAGE OF LIQUEFIED WATER!!!\u003c\/li\u003e\n\u003cli\u003eVERY GOOD VALUE FOR MONEY\u003c\/li\u003e\n\u003cli\u003eTOUCH PANEL\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003econtrol of heater, freon radiator - possibility of connecting air conditioning\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003epossibility to connect humidity sensor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePOLISH PRODUCT\u003c\/p\u003e\u003cp\u003eECS has over 14 years of experience in the production of equipment for industry, produces for the largest companies reputable, international.\u003c\/p\u003e\u003cp\u003eEach model of the air handling unit is created on the basis of well-thought-out solutions and proven technology.\u003c\/p\u003e\u003cp\u003eFilter- cartridge made as G4 class nonwoven fabric You do not have to buy expensive filters!!! . You can combine several filters eg G4+F9+H14 ps smog will be reduced in 80-90%\u003c\/p\u003e\u003cp\u003eUsed \"EC\" fans MANUFACTURED BY MADE in TAIWAN\u003c\/p\u003e\u003cp\u003eThe use of larger fans increases their service life, and soundproofs the ventilation system\u003c\/p\u003e\u003cp\u003eHousing\u003c\/p\u003e\n\u003cp\u003eThe housing is made of thin alum zinc sheets galvanized on both sides, which are specially shaped on numerical machine tools and permanently mounted with galvanized rivets to create a rigid self-supporting structure. The alum zinc material provides excellent protection for surfaces that come into contact with ventilation air and seals all housing components. In terms of acoustic and thermal, the casing is protected with a 30 millimeter layer of wool\u003c\/p\u003e\n\u003cp\u003eThe task of the ionizer is to naturally clean the air of impurities, such as: , mites, anaerobic bacteria, cigarette smoke dust, pollen, etc.\u003c\/p\u003e\n\u003cp\u003eThe ventilation system with recuperation allows up to 8 times reduction of ventilation heat losses.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\u003cp\u003eFilter:\u003c\/p\u003e\u003cp\u003eNonwoven fabric G4 (exhaust and supply)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVery tannin filter, possibility of replacing the non-woven fabric itself, cost PLN 2-4\u003c\/li\u003e\n\u003cli\u003ePossibility to configure any filter from G1 to U15 (filters used in the operating room)\u003c\/li\u003e\n\u003cli\u003ePossibility to combine several filters at the same time\u003c\/li\u003e\n\u003cli\u003eIndustrial work\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eControl:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePossibility of control in facilities with intelligent installations\u003c\/li\u003e\n\u003cli\u003ePossibility to adjust optimal fan operating parameters\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSpecification:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCAPACITY MAX 300m3\/h\u003c\/li\u003e\n\u003cli\u003ePower min 25W max 200W\u003c\/li\u003e\n\u003cli\u003ePressure up to 350Pa\u003c\/li\u003e\n\u003cli\u003eFAN CAPACITY \"EC\" 2x800m3\/h\u003c\/li\u003e\n\u003cli\u003eVOLTAGE 230 V 50 Hz\u003c\/li\u003e\n\u003cli\u003eHeat recovery efficiency from 65% to 92%\u003c\/li\u003e\n\u003cli\u003eEngine speed 2400 rpm\u003c\/li\u003e\n\u003cli\u003eNoise level db\/(A)3m 24-40\u003c\/li\u003e\n\u003cli\u003eMaximum operating speed up to 45C\u003c\/li\u003e\n\u003cli\u003eHousing material alumcynk sheet 0,7mm\u003c\/li\u003e\n\u003cli\u003eWool 30mm\u003c\/li\u003e\n\u003cli\u003eAir supply filter G4\u003c\/li\u003e\n\u003cli\u003eFilter extractor G4\u003c\/li\u003e\n\u003cli\u003eDiameter of stubs 200 mm\u003c\/li\u003e\n\u003cli\u003eRecuperator efficiency up to max 92%\u003c\/li\u003e\n\u003cli\u003eCOUNTERCURRENT recuperator\u003c\/li\u003e\n\u003cli\u003eRecuperator PLASTIC\u003c\/li\u003e\n\u003cli\u003eDirty filter signalling system\u003c\/li\u003e\n\u003cli\u003eElectronic Bapass, 100% Mechanical\u003c\/li\u003e\n\u003cli\u003eAnti-freeze system\u003c\/li\u003e\n\u003cli\u003eWeight about 40 kg QUALITY MUST WEIGH COMPARE WITH OTHER PRODUCTS OF THIS CLASS\u003c\/li\u003e\n\u003cli\u003eDimensions 370x750x615 mm\u003c\/li\u003e\n\u003cli\u003eTOUCH PANEL\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003etemperature measurement\u003c\/li\u003e\n\u003cli\u003eregulation of the supply force\u003c\/li\u003e\n\u003cli\u003eby-pass control\u003c\/li\u003e\n\u003cli\u003esetting a schedule\u003c\/li\u003e\n\u003cli\u003eheater control\u003c\/li\u003e\n\u003cli\u003eGWC control switching\u003c\/li\u003e\n\u003cli\u003eConfiguration of secondary radiator control\u003c\/li\u003e\n\u003cli\u003eswitching on the preheater\u003c\/li\u003e\n\u003cli\u003echoice of background color\u003c\/li\u003e\n\u003cli\u003eindication of soiled filter\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eFIREPLACE OPERATION MODE\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eAUTOMATIC TEMPORARY DEHUMIDIFICATION OF THE EXCHANGER\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eINTEGRATION WITH CONTROL PANEL AND AUTOMATION SYSTEMS\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003ePROGRAMMED CLOCK ZONES\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCHANNEL AIR CONDITIONING CONTROL-\u003c\/b\u003e\u003cb\u003econtrol of heater, freon radiator - possibility of connecting air conditioning\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eetc...\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e1:\u003c\/b\u003e Transition to thermostat and ventilation settings. A detailed description can be found in Chapter 6.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e2:\u003c\/b\u003e Return to Home Screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTERMOSTAT:\u003c\/b\u003e Operation of the thermostat is possible after enabling the option\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e3:\u003c\/b\u003e Go to the thermostat information screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e4:\u003c\/b\u003e Working with the schedule\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e5:\u003c\/b\u003e Christmas work\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e6:\u003c\/b\u003e Manual work\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e7:\u003c\/b\u003e Enabling GWC in automatic operation mode or disabling. GWC support is possible after enabling the option earlier\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e8:\u003c\/b\u003e Clicking sets simultaneous operation with the schedule for thermostat and ventilation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e9:\u003c\/b\u003e Clicking sets simultaneous Christmas work for thermostat and ventilation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVENTILATION:\u003c\/b\u003e Ventilation support is possible after connecting the AERO module\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e10:\u003c\/b\u003e Transition to ventilation information screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e11:\u003c\/b\u003e Working with the schedule\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12:\u003c\/b\u003e Christmas work\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e13:\u003c\/b\u003e Manual selection of ventilation running, where 3 is the highest speed, STOP means turning off the fans\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e14:\u003c\/b\u003e Attaches Outside the Home Program (NANO1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e15:\u003c\/b\u003e Attaches a holiday program\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e16:\u003c\/b\u003e Switches BY-PASS to automatic operation mode, continuously closes or opens it\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e17:\u003c\/b\u003e Switches ventilation to airing mode. The option is invisible with the OFF-HOME (NANO1) or HOLIDAY mode enabled.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCOLOR CONTROLLER ALLOWS CONNECTION OF DUCT AIR CONDITIONING\u003c\/p\u003e\u003cp\u003eSee the presentation of the MAX-VENT gen2 system, you can install it very easily, and from the channel on youtube Piotr Paruszewski you will learn how to do recuperation, how to mount devices, how to choose, how to design ventilation with recuperation and channel air conditioning--- ps it is not difficult, see and see for yourself\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSystem presentation:\u003c\/b\u003e ▶ https:\/\/youtu.be\/zwnY-pdrwj8\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePresentation of the entire GWC duct air conditioning:\u003c\/b\u003e ▶ https:\/\/youtu.be\/m8BvSsrRX5w\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDurability of our products:\u003c\/b\u003e ▶ https:\/\/youtu.be\/a3_OZIj2fLI\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSee recuperation assembly course:\u003c\/b\u003e ▶ https:\/\/youtu.be\/ZMhyH29QXEY\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHow to choose an exchanger for the air handling unit:\u003c\/b\u003e ▶ https:\/\/youtu.be\/PQYRlMa0cU4\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHow to select and make intakes and launchers:\u003c\/b\u003e ▶ https:\/\/youtu.be\/JaYdZvX_Jl0\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHow to choose a recuperator, ventilation units:\u003c\/b\u003e ▶ https:\/\/youtu.be\/T4-kbpZCiRg\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGreat anemostat theory for ventilation recuperation:\u003c\/b\u003e ▶ https:\/\/youtu.be\/hmj_Zri58Wo\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLinear diffuser mezzanine how to do:\u003c\/b\u003e ▶ https:\/\/youtu.be\/zW6ewKM40F4\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGreat theory of ventilation recuperation:\u003c\/b\u003e ▶ https:\/\/youtu.be\/TUGCt0jLmsk\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTheory of anemostat distribution:\u003c\/b\u003e ▶ https:\/\/youtu.be\/2DrL7inP8xA\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAnemostat distributions according to PN-83:\u003c\/b\u003e ▶ https:\/\/youtu.be\/tT88G79NqjE\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnecting distribution boxes:\u003c\/b\u003e ▶ https:\/\/youtu.be\/Uq1FjNinR7U\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAnemostat placements according to FASHION FACEBOOK:\u003c\/b\u003e ▶ https:\/\/youtu.be\/qKcPhyyynKM\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDistribution of anemostats Paruszewski's ideas:\u003c\/b\u003e ▶ https:\/\/youtu.be\/TzhaNNL84hU\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSee the source of knowledge Learn a new profession, there are dozens of videos on the channel, hundreds of tips from a person with 20 years of experience, you will find a compendium of knowledge about ventilation, recuperation, etc...\u003c\/p\u003e\u003cp\u003eSee the installation course of ventilation system recuperation in the MAX-VENT system and from the channel on youtube Piotr Paruszewski you will learn how to do recuperation, how to install devices, how to choose, how to design ventilation with recuperation and channel air conditioning\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/PQYRlMa0cU4\u003c\/p\u003e\u003cp\u003eHow to choose an exchanger for the ventilation unit, recuperator recuperation course odc1\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/JaYdZvX_Jl0\u003c\/p\u003e\u003cp\u003eHow to select and make intakes and launchers , recuperator course of recuperation assembly odc1a\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/T4-kbpZCiRg\u003c\/p\u003e\u003cp\u003eHow to choose a recuperator, ventilation units, installation course of ventilation recuperation odc3\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/hmj_Zri58Wo\u003c\/p\u003e\u003cp\u003eGreat anemostat theory in ventilation recuperation, installation course of ventilation recuperation odc4\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/zW6ewKM40F4\u003c\/p\u003e\u003cp\u003eLinear diffuser mezzanine how to make , installation course of ventilation recuperation section 4a\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/TUGCt0jLmsk\u003c\/p\u003e\u003cp\u003eGreat theory of ventilation recuperation , installation course of ventilation recuperation odc5\u003c\/p\u003e\u003cp\u003e▶ https:\/\/youtu.be\/2DrL7inP8xA\u003c\/p\u003e\u003cp\u003eTheory of anemostat distribution , installation course of ventilation recuperation section 6 part 1\u003c\/p\u003e\u003cp\u003eSee the source of knowledge Learn a new profession, there are dozens of videos on the channel, hundreds of tips from a person with 20 years of experience, you will find a compendium of knowledge about ventilation, recuperation, etc...\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGroup\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003enew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eInvoice\u003c\/td\u003e\n\u003ctd\u003eWith VAT invoice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eno brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eKind\u003c\/td\u003e\n\u003ctd\u003eheat recovery ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eManufacturer code\u003c\/td\u003e\n\u003ctd\u003eA-300 PODWIESZANA EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eRange of energy efficiency classes\u003c\/td\u003e\n\u003ctd\u003eA+ - G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametry\u003c\/td\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"computercars","offers":[{"title":"Default Title","offer_id":53367137042779,"sku":"12448015325","price":2940.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9355\/4523\/files\/Ventilation-Unit-Recuperator-300m3-h-PODW-EC.jpg?v=1781258246","url":"https:\/\/homy.lt\/products\/vedinimo-irenginys-su-rekuperatoriumi-podw-ec-300-m-val","provider":"homy.lt","version":"1.0","type":"link"}