Vandens lygio jutiklis su LCD, WiFi, Tuya, skirtas septiniams rezervuarams


Cena:
Akciju cena€138,67
Noliktava:
Pieejams noliktavā

Apraksts

Trumpai apie prekę

Prekė: Vandens lygio jutiklis su LCD, WiFi, Tuya, skirtas septiniams rezervuarams. Kategorija: Jutikliai.

  • Gamintojas: pcblab.io
  • Modelis: Czujnik sensor poziomu wypełnienia zbiornika

Wired liquid level sensor with LCD display with and 2.4GHz WiFi module

2 in 1:

✅Wired connection - 15 meters of cable

✅Connection to WiFi - preview in the TUYA or Smart Life app

Wired sensor with WiFi for TUYA and Smart Life apps

Liquid level monitoring

The modern liquid level sensor combines the reliability of wired communication with the convenience and mobility of WiFi. The device equipped with an LCD display and a WiFi wireless module allows you to control the filling status of the tank on an ongoing basis, set warning thresholds and receive notifications in the TUYA or Smart Life application.

This solution will work well in homes, gardens and industrial installations – wherever failure-free operation and fast access to data count.

The most important advantages of the sensor

  • Stable wired communication – less susceptibility to electromagnetic interference and physical obstacles, which ensures smooth and reliable operation.
  • Safe 9V DC power supply – the device has an included power supply, so you do not have to worry about dead batteries.
  • Readable LCD – the current level of filling visible on the screen as a percentage.
  • Monitoring of minimum and maximum thresholds – set alerts informing about the liquid falling below the minimum or exceeding the maximum level.
  • High protection class IP66 – housing resistant to water and dust, allowing safe use outdoors and in difficult conditions.

2 in 1: wired and wireless connection

Advantages of wired connection

  • Wired communication: Less susceptibility to electromagnetic interference and physical barriers, which ensures stable speed and reliable operation.
  • Safe voltage supply: The device is powered by 9VDC DC voltage. The power supply is included, eliminating the need to replace or recharge the battery.
  • Fill monitoring: The ability to set the minimum and maximum level of liquid in the tank and receive notifications when these values are exceeded.
  • High protection class IP66: Dust and water resistant housing, allowing safe operation in harsh environments.

Wireless connection (WiFi)

  • Remote preview in the app: Ongoing monitoring of liquid levels on your smartphone from anywhere in the world.
  • Push notifications: Quick information about falling below the minimum or exceeding the maximum, even when away from home.
  • Integration with home automation: Possibility to associate the sensor with other devices in the TUYA ecosystem (e.g. starting the pump, closing the valve).
  • Free application: Support in both the TUYA Smart and Smart Life applications – choose according to user preferences.
  • Measurement history: Access to record liquid level changes for better wear analysis and replenishment planning.

DESCRIPTION OF THE SET

The device consists of:

  1. Level sensor, which is mounted in the tank. The sensor communicates with wired with LCD display.
  2. Communication cable with a length of 15 meters (4-wire cable)
  3. LCD display (wired connects to the sensor) - receiver/transmitter, which serves as a bridge between the sensor and the WIFI router. The display is installed in the room (it cannot be exposed to weather conditions) within the range of the WiFi signal. The display communicates wired with a level sensor.
  4. Power supply 5VDC, 1A - to power the LCD display (power supply to the sensor is given from the LCD display)
  5. Phone app - TUYA or Smart Life - downloadable, free, from Google Play Store or App Store

Application

  • Water tanks and rainwater containers
  • Garden and irrigation installations
  • Aquaculture, swimming pools, ponds
  • Industrial and commercial tanks

SPECIFICATION

  • Length of communication cable - 15 meters
  • Internet connection - WiFi 2.4GHz
  • Minimum distance of the sensor from the liquid - 10cm (0.1m)
  • Maximum tank depth - 300cm (3 meters)
  • Sensor and receiver power supply - 5V DC, 1A - power supply included
  • LCD display
  • Thread: BSF 2 and 1/4 = 54,356 mm
  • Sensor tightness class: IP66

Functions

  • setting minimum thresholds
  • setting maximum thresholds
  • push notifications (in-app)
  • history of measurements (in the application)

The set includes

  • Wired sensor with WiFi module
  • AC adapter 5V DC, 1A
  • Operating instructions

We provide detailed guidelines for the correct installation of the liquid level sensor based on the attached illustration:

Correct orientation of the sensor

  • The sensor should always be mounted perpendicular to the surface of the liquid
  • Incorrect positioning of the sensor at an angle will result in incorrect readings

Location relative to water supply

  • The sensor should be installed away from the water inlet
  • Installation too close to the water supply can cause a pseudo-echo phenomenon, interfering with correct measurements

Distance from the walls of the tank

  • Maintain adequate sensor distance from the side walls of the tank (partitions)
  • Installation too close to the wall (partitions) will result in a strong pseudo-echo, which will significantly affect the accuracy of measurements

Sensor assembly and wave distribution

1. Principle of operation of the sensor

The liquid level sensor is mounted on the top of the tank and emits a measuring beam with an angle of ±30°. This beam shall comprise a conical area in which the distance to the surface of the liquid is measured. The correct measurement takes place only if there are no obstacles in the reflection area.

2. Selection of tank

To ensure proper operation of the sensor, the appropriate diameter of the tank (D) in relation to its height (H) should be selected:

  • H = 3 m → D > 1,6 m
  • H = 2 m → D > 1,1 m

For round and square tanks, the diameter D should be counted as the largest internal dimension of the tank.

3. Proper installation of the sensor

  • The sensor should be mounted centrally above the surface of the liquid so that the measuring beam does not encounter obstacles such as pipes, structural elements or tank walls.
  • Avoid mounting the sensor over elements that may cause wave reflection interference, e.g. above the pipes, close to the walls or under protruding elements.
  • The sensor shall be directed vertically downwards so that the beam covers the entire surface of the liquid in the designated reflection area.

4. The most common assembly errors

  • Mounting the sensor over an obstacle (e.g. pipe) causes interference with the measurement.
  • Setting the sensor too close to the tank wall leads to incorrect readings by reflections from the wall.
  • Installation under protruding elements or at an angle other than vertical prevents proper measurement of the liquid level.

Specifications

Group Name Value
Parametry Condition new
Parametry Invoice With a VAT invoice
Parametry Series Tuya
Parametry Brand pcblab.io
Parametry Manufacturer code Czujnik sensor poziomu wypełnienia zbiornika
Parametry EAN (GTIN) 5906124219180
Parametry Packaging status original

Piegādes termiņš visā Lietuvā: 5-7 darba dienas.
Piegādes cena uz norādīto adresi: 3 eiro

Saistītās preces

Nesen skatītās