Dūmų ir anglies monoksido detektorius su LCD ekranu 2in1


Kaina:
Akcijos kaina€34,36
Sandėlys:
Yra sandėlyje

Aprašymas

Trumpai apie prekę

Prekė: Dūmų ir anglies monoksido detektorius su LCD ekranu 2in1. Kategorija: Jutikliai.

  • Gamintojas: BAREX
  • Modelis: Czujnik dymu i tlenku węgla

⭐2 in 1 Smoke and Carbon Monoxide Sensor with LCD Display

✅ 24/7 security – the safety of your family and home

Modern 2-in-1 sensor that detects both smoke and carbon monoxide (CO). Equipped with a sensitive electrochemical and optical sensor, it quickly responds to the threat by informing with a loud audible alarm and a light signal.

✅ LCD display – shows the concentration of CO in the air (in ppm).

✅ LED signaling – green (normal operation), red (alarm), yellow (low battery or fault).

✅ Double protection – detects both carbon monoxide and smoke.

✅ alarm – above 85 dB, audible throughout the apartment.

✅ Easy installation – wall or ceiling mounting, mounting hardware included.

Battery powered – no need to connect to the mains, also works in case of power failure.

⭐Why is this sensor necessary?

✅Carbon oxide, also known as carbon monoxide, is a silent killer – it is odorless, colorless and imperceptible to humans. Already a small concentration can cause dizziness, nausea, and in extreme cases – death.

✅Combining a smoke and carbon monoxide detector in one device is the best protection for you and your loved ones. The sensor responds immediately by triggering a loud alarm and traffic lights, giving you time to safely evacuate and call for help.

⚙ Technical specification:

✅Type: Smoke detector + carbon monoxide sensor (2 in 1)

✅Sensor: electrochemical + photo-optical

✅Measurement range CO: 0 to 999 ppm

✅Measurement accuracy: ±10 ppm

✅Alarm volume: ≥ 85 dB

✅ Power supply: AA batteries (no need to connect to mains)

✅Moisture: 10 to 90% RH

✅Dimensions: approx. 104 × 35 mm

✅Certificates: CE, RoHS

❗Contents of the set:

  • Smoke and carbon monoxide sensor
  • Assembly elements (screws, pegs)
  • Operating instructions

⭐Advantages for the user:

✔ Two devices in one – saving space and money.

✔ Constant air quality control – LCD display shows CO level in real time.

✔ Loud warning signal – it is impossible to miss it, even at night.

✔ Simple installation – install yourself in minutes.

✔ Reliable operation – also works in case of power failure.

❓The sensor "howls" or shows the concentration of CO, although there is no smoke or combustion - why?

⚠ Common causes:

1) low battery – the sensor signals this with sound; replace the batteries with new, good quality;

2) the CO sensor reacts to real, imperceptible to humans traces of carbon monoxide (exhaust gases from the street, garage, fireplace, cigarette smoke) — this is the action as intended;

3) ending period of sensor operation. If after replacing the battery and ventilation the alarm still occurs for no reason, take it seriously: first exclude the real threat (air, leave the room), and if the device is still malfunctioning – report a complaint under the standard Allegro procedure.

---

❓Batteries discharge very quickly – what to do?

✅ Use new good quality alkaline batteries. Backlit LCD display increases power consumption – if the model allows, limit continuous backlighting. At low temperatures and with weak batteries, the service life decreases.

⚠ Short, regular beeps are a signal of battery discharge (necessity to replace), not a fault.

---

❓How to properly mount the sensor – on the ceiling or low?

✅ It depends on the threat and is crucial: the smoke rises upwards, so for smoke detection the sensor is mounted high (on the ceiling or just below it). Carbon monoxide is mixed with air, so the CO sensor is usually mounted at a height of approx. 1 to 1,5 m (at breathing height), a few meters from the source (furnace, fireplace, gas heater).

⚠ If in doubt, consult a chimney sweep or fire brigade and follow current guidelines.

---

❓The sensor did not react to smoke during the test / reacts slowly.

⚠ Response time and sensitivity depend on smoke type and density, distance from source and installation location.

✅ Test the device with the TEST button according to the instructions, not with real smoke (candle, cigarette) — different types of particles are detected differently. For complete protection in high-risk rooms, we recommend several sensors in different places and not relying on one device.

---

❓Is it a smoke detector, CO or both at the same time?

✅ This 2-in-1 device detects both smoke (photo-optical sensor) and carbon monoxide (electrochemical sensor). The LCD display shows the current CO level (range 0 to 999 ppm). CO and smoke are two different hazards, and the mounting height is a compromise between them – with specific requirements, consider separate sensors for each hazard.

---

❓The alarm seems too quiet to me.

✅ Alarm volume is ok. 85 dB up close — a typical value for this class. Mount the sensor where the signal will be heard from the rooms where the household members are staying (especially the bedroom). In larger homes, we recommend several sensors.

---

❓The sensor makes "strange sounds", crackles or after a few/several months shows an error.

✅ Short signals are usually information about discharged batteries – start by replacing. Error message or unusual sounds despite new batteries may mean the end of the sensor’s life or malfunction. Gas and smoke sensors have a limited lifespan – after it expires, the device should be replaced. In case of permanent irregularities, submit a complaint under the standard Allegro procedure.

---

❓Does the sensor require electricity or WiFi?

❌ No. It is powered by AA batteries and operates independently, without electricity or WiFi – even in the absence of electricity, provided that the batteries are functional.

---

❓How to test and maintain the sensor?

✅ Regularly (e.g. once a month) press the TEST button to check the audible and light alarm. Keep the holes clean (dust interferes with the measurement), do not seal them and do not paint the device. Replace batteries after the first discharge signal. Device for indoor use in dry rooms (10% to 90% RH humidity).

Specifications

Group Name Value
Parametry Condition new
Parametry Sensor type smoke
Parametry Series 2w1 z wyświetlaczem LCD
Parametry Brand BAREX
Parametry Power supply batteries
Parametry Additional features audible alarm, warning light signal, display
Parametry Batteries included no
Parametry Manufacturer code Czujnik dymu i tlenku węgla

Pristatymo terminas visoje Lietuvoje: 5-7 d.d.
Pristatymo kaina nurodytu adresu: Pristatymas nemokamas

Susijusios prekės

Nesenai žiūrėtos