Pristatymo terminas visoje Lietuvoje: 5-7 d.d.
Pristatymo kaina nurodytu adresu: 3 eur
Aprašymas
Trumpai apie prekę
Prekė: Elektroninis pH matuoklis su automatinio kalibravimo funkcija. Kategorija: Filtruojantys ąsočiai ir buteliai.
- Gamintojas: Tessa
- Modelis: other (PH-03)
- Medžiaga: synthetic material
- Waterproof housing
- Interchangeable measuring electrodes
- Simultaneous measurement of pH and temperature
- pH measurement range: 0,00 - 14,00 pH
- Measurement resolution: 0,01 pH
- Accuracy: ± 0,01 pH
- Temperature measuring range: 0,1 - 60,0 °C
- Measurement resolution: 0,1 °C
- Accuracy: ± 0,5 °C
- Operating temperature: 0 - 60 °C
- Liquid Temperature Compensation (ATC)
- Calibration: factory, electronic, two-point/three-point
- All meters are ready for use (checked and calibrated before shipping)
- Dimensions: 183mm X 37mm
- Weight: 88g meter (246g whole set)
- Power supply: 3 x 1,5V LR44 battery (set in meter and spare included)
- Automatic shutdown function after 5 minutes of inactivity
- Brand new, calibrated product
- Electronic pH tester with ATC function
- Buffer for calibration 4.01, 6.86 and 9,18 pH (for reconstitution with known pH)
- Plastic box/case
- Detailed instruction in English
- Detailed instructions in Polish can be downloaded from the "Additional information" tab located at the bottom of the page.
- Battery compartment cover
- Indicator battery level
- pH display
- Temperature display
- On button
- Calibration and change button °C/°F
- Measurement value stop button
- Maximum immersion level
- Protective cap of the measuring electrode
- Measuring electrode
- Fishkeeping
- gastronomy
- agriculture, forestry, water protection
- gardening, hydroponics
- Pools & Spas
- food industry
- Chemical industry
- distilling and brewing
- ph determination of water, urine, sewage, etc.
- wherever pH reagent measurement is needed
ATC function (Automatic Temperature Compensation) - temperature measurement and compensation indication of the tester in the range of 0-60°C. Thanks to this, we obtain an accurate result of acidity of a given liquid.
Due to the pH variability of the liquid relative to its temperature, only an acid meter with the ATC function allows to obtain a reliable result consistent with the actual average value.
The pH tester complies with EU directives and is marked with the CE mark. In addition, the pH tester is made of materials that meet the strict requirements of the EU ROHS directive.
- Make 3 solutions with known pH using 250 ml of distilled water each and calibration buffers (4.01; 6.86; 9,18 pH included).
- Dip the tester electrode into a solution with pH 6,86 (at 25℃) and wait for the reading to stabilize.
- Press the "CAL" button (calibration) for 5 seconds and release. The display will display a flashing "CAL" then flashing 6,86 when the calibration for this point stops flashing has been completed.
- Clean the electrode in distilled water and dry.
- Repeat the procedure in sections 2 and 3 for solutions 4,01 and 9,18 pH.
- Clean the electrode in distilled water and osusz.Umieść meter back in buffer solution to test calibration. If it is incorrect, repeat the calibration.
- Remove the protective cap. If crystals appear under it, this is not a cause for concern, this is normal with pH tester electrodes. The problem will disappear after rinsing the electrode with cleaning liquid/water.
- Turn on the tester with the "ON/OFF" button and immerse the pH meter electrode in the test liquid. Gently mix until the displayed value stabilizes, then read the value from the display.
- After the measurement, rinse the electrode with water and wipe with a cloth. Put on a protective cap
- Clean the electrode with distilled water each time before and after use.
- Do not touch the sensor electrode, as the oil on the skin can damage the sensor and affect the readings.
- Store the meter with a few drops of electrode storage fluid in the protective cap (e.g. GIB KCL or Growth Technology). Lack of this action may affect the correctness of readings and the life of the device.
- Large differences in readings can be due to the need for calibration, a dry electrode or weak batteries.
Re-calibration is required for:
- battery replacement,
- very frequent measurements,
- the display shows the message "ERR",
- long periods without measurements,
- the need for very accurate measurements.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Brand | Tessa |
| Parametry | Model | other (PH-03) |
| Parametry | Manufacturer code | PH-03 |
| Parametry | EAN (GTIN) | 5906660431350 |
| Parametry | Dominant color | silver/gray |
| Parametry | Material | synthetic material |
| Parametry | Total capacity | 100 l |
| Parametry | Product height | 18 cm |
| Parametry | Product weight with unit packaging | 0.25 kg |
| Parametry | Type | not specified |
| Parametry | Number of cartridges included in the kit | 1 |
| Parametry | Cartridge wear indicator | none |








