Pulso oksimetras JUMPER, medicininis sertifikatas, OLED ekranas


Kaina:
Akcijos kaina€35,07
Sandėlys:
Yra sandėlyje

Aprašymas

Trumpai apie prekę

Prekė: Pulso oksimetras JUMPER, medicininis sertifikatas, OLED ekranas. Kategorija: Pulso ir deguonies matuokliai.

  • Gamintojas: Jumper
  • Modelis: JPD-500D
  • Spalva: black

The device has a medical certificate class IIa

  • Colour OLED display
  • Display with large font
  • Adjustable brightness
  • Perfusion index
  • Function: pulse sound and alert
  • Compact, you can take it anywhere with you - to work, for a walk
  • Extremely low power consumption
  • Simple and intuitive to use
  • Reliable and accurate measurement
  • Automatic shutdown in case of inactivity
  • Certificates: CE for medical devices, TUV
  • Comes with case, strap and batteries

Designed for ADULTS AND CHILDREN, it can be used for people with low pressure.

The pulse oximeter is notified to the Office for Registration of Medicinal Products, Medical Devices and Biocidal Products.

  • Saturation: blood oxygen concentration (Spo2 35%-100%)
  • Heart rate - (bpmPR 25- 250 beats/min)
  • Perfusion rate, helpful for people with poor circulation

Oxygen saturation is the percentage of oxyhemoglobin (HbO2) in combination with oxygen against whole combined hemoglobin (Hb). This is an important physiological parameter of breathing and circulation.

The oxygen saturation of arterial blood in the normal human body is 98%. Oxygen saturation is an important indicator of the state of oxygen in the human body. In general, normal oxygen saturation values must not be lower than 94%. If the measured oxygen saturation values are less than 94%, it is considered insufficient oxygen. Heart rate is the number of heart rate beats per minute. In general, each person’s heart rate ranges from 60 to 90 beats per minute. The perfusion index (PI) usually reflects the perfusion state of the patient’s limb and also shows the precision of instrument detection; that is, the test can still be performed even under low or weak perfusion conditions. The PI of a normal human body is 3% or greater.

A. Battery cover lock

B. Battery cover

C. OLED Display

D. Power and function button

  1. Symbol of oxygen saturation
  2. The value of oxygen saturation
  3. Plethysogram
  4. Battery Level Indicator
  5. Heart rate symbol
  6. Perfusion Index
  7. Measured heart rate
  8. Bar chart

The device is necessary for:

  • people with respiratory disorders, asthmatics
  • athletes
  • people with cardiovascular problems
  • people who want to control their vital signs

The finger pulse oximeter measures the blood oxygen saturation and heart rate of the human body through the finger artery. It applies in many places.

Saturation is marked with the symbol Spo2 and is given as a percentage. Its correct value in a healthy person is 93-99%

Just insert your finger into the probe and turn on the pulse oximeter, after a few seconds the result can be read directly from the display - SpO2 value, PR heart rate, heart rate wave, etc.

  • Easy one-button control
  • Small size
  • Economical in energy consumption
  • Reliable measurement
  • Automatic shutdown
  • Dimensions: 62,0 x × 37,0 x 33,1 mm (W x D x H)
  • Weight: 42,5 g (including two AAA batteries)
  • Peak wavelength range of light emitted by the probe: red light 660 nm ± 3;
  • Infrared light 905 nm ± 5.
  • Maximum optical output power of the probe: 1,2 mw for infrared light (905 nm).
  • Operating temperature: 5°C to 40°C (41°F to 104°F)
  • Relative humidity: 15% - 80% non-condensing
  • Pressure height: 70 kPa to 106 kPa
  • Batteries: DC 3V (2 pcs. AA batteries)
  • SpO2 alert: upper limit = 100 lower limit = 94
  • Heart rate alert: upper limit = 130 lower limit = 50
  • Alert status: when the alert switch is on and the current measured value goes beyond
  • set by the range of the alarm parameter, the pulse oximeter emits a warning sound.
  • Oxygen saturation measurement range: 35% to 100%
  • Heart rate measurement range: 25 bpm to 250 bpm
  • Distribution: 1% / 1bpm
  • SpO2 measurement accuracy: ± 2% (70% to 100%)
  • Heart rate measurement accuracy: ±2 bpm
  • SpO2 alert range: upper limit: 50% to 100%, lower limit: 50% to 100%
  • Heart rate alert range: upper limit: 25bpm to 250 bpm, lower limit: 25 bpm to 250 bpm
  • SpO2 Alert Error: ± 1% of set value
  • Heart rate alert error: Larger with ± 10% set value and ± 5 bpm
  • Storage and transport: packed products should be stored in well-ventilated rooms without corrosive gases and with ambient temperature from –10°C to +50°C, relative humidity 10% - 93% (non-condensing) and atmospheric pressure from 50 to 106 kPa.
  • Display Type: Color OLED Display, 4 Display Directions
  • Battery Level Icon
  • Automatic shut-off function
  • Battery powered: 2 alkaline batteries (AAA) - included
  • Finger pulse oximeter JPD-500D
  • Lanyard for wearing a pulse oximeter
  • Case for storing the device
  • User manual in Polish included in the box
  • 2x AAA battery
  • Original manufacturer's packaging

Specifications

Group Name Value
Parametry Condition new
Parametry Invoice With VAT invoice
Parametry Medical device yes
Parametry Medical device type medical device or in-vitro diagnostic medical device
Parametry Manufacturer of a medical device Jumper
Parametry Brand Jumper
Parametry Model JPD-500D
Parametry Color black
Parametry Power supply batteries
Parametry EAN (GTIN) 6951740500203
Parametry Manufacturer code Jumper 500D
Parametry Batteries included yes
Parametry Functions audible alarm,visual alarm,automatic shutdown,battery level indicator,heart rate graph

Pristatymo terminas visoje Lietuvoje: 5-7 d.d.
Pristatymo kaina nurodytu adresu: 3 eur

Susijusios prekės

Nesenai žiūrėtos