Pristatymo terminas visoje Lietuvoje: 5-7 d.d.
Pristatymo kaina nurodytu adresu: 3 eur
Aprašymas
Trumpai apie prekę
Prekė: Vandens filtras su UV sterilizatoriumi Nordic Tec 55W, PHILIPS lempa, PZH sertifikatas. Kategorija: Vandens filtrai ir minkštikliai.
- Gamintojas: Nordic Tec
- Modelis: UV-55W
- Talpa: 5 l
UV lamp for water 55W NORDIC TEC UV55-PH
Complete set with 55W power and 3/4" connections with PHILIPS filament
The kit includes all mounting parts for assembly.
✅ Device of the renowned brand Nordic Tec➡ UV filter 55W with PZH certification.
Details of 55W Water UV Sterilizer Kit
- Reaction chamber made of stainless steel S304
- Response chamber dimensions: 975mm x ⌀64mm
- Power of filament/UV-C radiator - 55W
- Filament included: PHILIPS TUV 55W G55 T8
- Water connections: 3/4" / DN 20 External thread
- Nominal flow:
at UVC dose 300 J/m² - 44,17 l/min
at UVC dose 400 J/m² - 30,83 l/min
- Most common use - apartment / house for 2-5 people
This is a potential selection, it does not take into account additional factors of water consumption, such as: watering livestock, watering plants or additional bathrooms used from time to time by guests.
Most often, this model of UV sterilizer lamp is used to connect at the entrance of water to the building, in order to sterilize all water consumed by the household. It can be water from a well, from its own intake - or water from a water supply with a tendency to show biological contamination.
UV lamps are a remedy for contamination of E-Cola water with similar strains.
❗ UV sterilizer is not suitable for working with water with the addition of salt and salt water. ❗
- Working pressure - recommended up to 10 bar
- Handles and O-rings included
- Transformer with ground cable included (230 V)
- Diodic filament work/burnout signal
PZH certificate - UV sterilizer Nordic Tec 55W has a certificate allowing for use with drinking water
➡ Unfortunately, most of the UV sterilizers offered by the competition do not have this certification, despite legal requirements in this regard.
PZH certification for UV water lamps is a legal requirement: Hygienic Certificate means legal approval for use with drinking water and guarantees that the product does not contain materials harmful to health. All components have been tested and approved for use. Hygienic Certificate PZH in accordance with Polish law is required in the case of products intended for contact with drinking water.
✅ Choose a UV filter with guarantee of safe use and health. Buy only certified UV devices that guarantee safety and no harmful effects on health. Remember that UV filters without the PZH Certificate should not be used in contact with drinking water and are only suitable for sterilization of water not intended for consumption.
Each set of UV lamps is opened in the shipping warehouse to check the completeness and verify that the glass elements have not been damaged in any way during transport and storage - to be as sure as possible that any defective or damaged glass elements were not sent to the customer. For this reason, lamps may bear signs of opening - we assure you that we sell only NEW and UNUSED goods.
Recommended continuous operation mode - UV lamp for water - 55W:
- The UV to sterilizer should work in a continuous system, i.e. 24/7 - only then constitutes a continuous barrier to E-Cola and similar biological contaminants.
- It is not recommended to turn off the lamp for a relatively short time - e.g. for the time of going to work or at night. The lamp should be turned off when the household members are not there for more than 1-2 days (e.g. weekend trip) or longer absence
- The UV filament is adapted to continuous operation - also many months old, it is not harmful to this type of filament.
- It is strongly discouraged to synchronize the lamp switching on with the flow (e.g. with a hydrophore) - this is counter-effective when it comes to the sterilization of water itself and additionally leads to premature burning of the filament. In general, frequent switching on and off of the UV water sterilizer for short periods is discouraged.
Choose PHILIPS branded filaments
! IMPORTANT!
- Direct contact with UV rays for the eyes and skin is dangerous!
- Do not start the lamp when it is outside the so-called. Reaction chamber!
IMPORTANT USAGE/ASSEMBLY GUIDELINES
Read it to avoid damaging the filament!
1. When installing, avoid touching the filament glass with your fingers (this can cause it to burn out quickly).
2. Before installation, clean the filament and menzurka, preferably using an alcohol wipe. If this action is abandoned, the filament can burn out much faster.
3. Do not turn on the filament when it is outside the reaction chamber. He's threatening eye damage. In order to check the filament operation, you can use diode signaling on the transformer or check gently whether a bluish color light comes out through the holes (without looking directly at them).
4. Before the sterilizer, it is recommended to use any mechanical filter to prevent particulate matter from entering the chamber.
Specifications
| Group | Name | Value |
|---|---|---|
| Parametry | Condition | new |
| Parametry | Invoice | With VAT invoice |
| Parametry | Brand | Nordic Tec |
| Parametry | Kind | filter |
| Parametry | Capacity | 5 l |
| Parametry | Product weight with unit packaging | 5 kg |
| Parametry | Manufacturer code | UV-55W |
| Parametry | EAN (GTIN) | 652733152817 |
| Parametry | Dominant color | silver/gray |
| Parametry | Model | UV-55W |






