Vandens UV sterilizavimo lempa Nordic Tec PHILIPS 30W, su PZH sertifikatu


Kaina:
Akcijos kaina€207,75
Sandėlys:
Yra sandėlyje

Aprašymas

Trumpai apie prekę

Prekė: Vandens UV sterilizavimo lempa Nordic Tec PHILIPS 30W, su PZH sertifikatu. Kategorija: Vandens filtrai ir minkštikliai.

  • Gamintojas: Nordic Tec
  • Modelis: UV-30W
  • Talpa: 3 l

UV filter for water, complete set with 30W power

with PHILIPS filament

➡ PZH certified water filter

Water sterilizer - bactericidal lamp 30W

  • Reaction chamber made of stainless steel S304
  • Response chamber dimensions: 975mm x 64mm
  • Power of filaments/radiators - 30W
  • Connections: 3/4"
  • Nominal flow:

at UVC dose 300 J/m² - 29,17 l/min

at UVC dose 400 J/m² - 20,83 l/min

  • Most common use - apartment / house for 2-4 people

This is a potential selection, it does not take into account additional factors of water consumption, such as: watering livestock, watering plants or additional bathrooms used from time to time by guests. It is a UV water lamp most commonly used at the entrance to the house, e.g. for disinfection of water from a well or from an urban intake.

❗ 30W S304 - UV sterilizer is not suitable for working with water with salt and salt water.

  • Working pressure - 10 bar
  • Handles and O-rings included
  • Transformer with ground cable included (230 V)
  • Diodic filament work/burnout signal
  • PHILIPS filaments with expected service life - up to 8 - 10 000h

PZH certificate - UV sterilizer Nordic Tec 30W has a certificate allowing for use with drinking water

➡ Unfortunately, most of the UV lamps offered by the competition do not have this certification, despite legal requirements in this regard.

PZH certification for water filts is a legal requirement: Hygienic Certificate means legal approval for use with drinking water and guarantees that the product does not contain harmful materials. All elements including steel, gaskets, glass have been tested and approved for use. The PZH certificate in accordance with Polish law is required in the case of products intended for contact with drinking water.

Bet on a product with guarantee of safe use and health. Buy only certified UV lamps.

➡ Remember that UV filters without a Hygienic Certificate should not be used to sterilize drinking water.

Each set of UV lamps is opened in the shipping warehouse to check the completeness and verify that the glass elements have not been damaged in any way during transport and storage - to be as sure as possible that any defective or damaged glass elements were not sent to the customer. Boxes may show signs of opening after checking the goods in stock - but we assure you that we only sell NEW and UNUSED goods.

Recommended operating mode of UV lamp for water - 30W - continuous operation:

  • The UV 30W (or other) to sterilizer should work in a 24/7 system - only then it is a continuous barrier to E-Cola and similar biological contaminants.
  • It is not recommended to turn the UV lamp on/off for a relatively short time - e.g. for the time of going to work or at night. The lamp should be turned off only if the household members are not there for more than 1-2 days (e.g. departure for the weekend) or a longer absence of residents of the building.
  • The UV filament is adapted to continuous, even many months of operation - this is not harmful to TUV filament of this type, as opposed to frequent switching on for a short time.
  • It is strongly discouraged to synchronize the lamp switching on with the flow (e.g. with a hydrophore) - this is counter-effective when it comes to the sterilization of water itself and additionally leads to premature burning of the filament. In general, frequent switching on and off of the UV water sterilizer for short periods is discouraged.

Nordic Tec UV lamp filaments - PHILIPS brand

Choose branded PHILIPS filaments - you will have no problem buying a replacement bulb, PHILIPS UV-C filaments are very easily available in every European country.

! IMPORTANT!

  • Direct contact with UV rays for eyes and skin is dangerous - UV sterilizer for water should be activated only when the lamp is in the steel chamber

IMPORTANT OPERATING/ASSEMBLY GUIDELINES

Read it to avoid damaging the filament!

1. When installing, avoid touching the filament glass with your fingers (this can cause it to burn out quickly).

2. Before installation, clean the filament and menzurka, preferably using an alcohol wipe. If this action is abandoned, the filament can burn out much faster.

3. Do not turn on the filament when it is outside the reaction chamber. He's threatening eye damage. In order to check the filament operation, you can use diode signaling on the transformer or check gently whether a bluish color light comes out through the holes (without looking directly at them).

4. Before the sterilizer, it is recommended to use any mechanical filter to prevent particulate matter from entering the chamber.

Specifications

Group Name Value
Parametry Condition new
Parametry Invoice With VAT invoice
Parametry Brand Nordic Tec
Parametry Kind filter
Parametry Capacity 3 l
Parametry Product weight with unit packaging 5 kg
Parametry Manufacturer code UV-30W
Parametry EAN (GTIN) 685071126752
Parametry Dominant color silver/gray
Parametry Packaging status original
Parametry Model UV-30W

Pristatymo terminas visoje Lietuvoje: 5-7 d.d.
Pristatymo kaina nurodytu adresu: 3 eur

Susijusios prekės